The User Manual of 580 Series General Frequency Converter


The wiring of control signal output terminal



Download 23,63 Mb.
bet27/63
Sana31.12.2021
Hajmi23,63 Mb.
#261617
1   ...   23   24   25   26   27   28   29   30   ...   63
Bog'liq
580 Manual EV1.0 中性最终版20140630

The wiring of control signal output terminal

3) DO digital output terminal:

When digital output terminal is used to drive the relay, the absorber diode shall be installed additionally on both sides of the relay coil, or else, DC 24V power supply may be damaged. The drive capacity shall not be more than 50mA.

Note: The polarity of absorber diode must be installed appropriately, as shown in the following figure. Otherwise, when there is output of digital terminal, DC 24V power supply may be damaged immediately.



Fig. 3-27 The wiring diagram of digital output terminal

Chapter 4 Operation Display and Applications

4.1 Introduction of operation and display interface

The function parameter modification, working condition monitoring of frequency converter, operational control of frequency converter (start and stop) and other operations of the frequency converter can be finished by means of operation panel. Its appearance and function area are as shown in the following figure:

Fig. 4-1 Operation panel diagram

The function indicator lights are described as follows:

● RUN: When the light is on, the frequency converter is in running; when the light is off, the frequency converter is in stop.

● LOCAL/REMOT: Indicator lights for keyboard operation, terminal operation and remote operation (communication control):


○ LOCAL/REMOT: OFF

Start and stop control mode of the panel

● LOCAL/REMOT: ON

Start and stop control mode of the terminal

LOCAL/REMOT: Flash

Communication start and stop control mode

● FWD/REV: For FWD/REV indicator light, it is in reverse running when the light is on.

● TUNE/TC: For tuning/torque control/ failure indicator light, when the light is on, it is in torque control mode; when the light flashes slowly, it is in tuning state; when the light flashes quickly, it is in failure state.



: Unit indicator light is used to indicate the unit of current data displayed and cover the following units: (○ means that the light is OFF; ● means the light is ON)

: Frequency unit: Hz

: Current unit: A

: Voltage unit: V

: Rotating speed unit: RMP

: Percentage %




Download 23,63 Mb.

Do'stlaringiz bilan baham:
1   ...   23   24   25   26   27   28   29   30   ...   63




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish