Support various motors

Support the vector control of three-phase AC asynchronous motor and three-phase AC permanent magnet synchronous motor.



Rich control methods

Apart from vector control of speed sensor, vector control of non-speed sensor and V/F, the machine also support separation control.



Various encoders

Support differential encoder, open collector encoder, rotary transformer, etc.



The vector control algorithm of brand new non-speed sensor

Compared with brand new SVC (vector control of non-speed sensor), 6000 frequency converter can bring better low-speed stability and stronger low-frequency load capacity. SVC torque control is also supported. There are further rich functions and the additional functions of 580 on the basis of 6000 are listed as follows.




Function

Description

Motor protection

against overheat



After IO expansion card is selected, AI3 can receive the input from motor temperature sensor (PT100, PT1000) to achieve motor protection against overheat

Rapid current limit

Prevent the frequency converter from frequency overcurrent

Multi-motor switch

There are four sets of motor parameters and four motor switching can be controlled

Recover user parameter

This function supports that the customer saves the parameters or restore parameers.

AIAO with higher

accuracy


Based on delivery calibration (or field calibration), AIAO accuracy range is within 20mv

User customized

parameter display



The user can customize functional parameter to be displayed

User change parameter display

The user can check the modified functional parameters

Optional troubleshooting method

After specific failure occurs, the user may determine the actions of frequency converter: free stop, deceleration stop and continuous operation. The frequency for continuous running can be also selected.

PID parameter switch

Two sets of PID parameters are available and can be switched by the terminal or freely switched according to deviation

PID feedback loss

detection



Set PID feedback loss detection value and realize the protection during PID running

DIDO positive and

negative logic



The user should set the positive and negative logic for DIDO

DIDO response delay

The user should set DIDO response delay time

Timing run

Support timing run in maximum range of 6,500 minutes



Download 23,63 Mb.

Do'stlaringiz bilan baham:
1   2   3   4   5   6   7   8   9   ...   63




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish