a
-

if v
S1
(t
=
100 sin120
p
t V 
and v
S2
(t
=
100 sin(120
p
t
-
60
°
) V.
0.4 

0.5 

0.5 

0.1 mF 
5 mH 
4 mH 

– 

– 
v
S2 
(
t

v
S1 
(
t
)


Fig. 7.12-10 
39. Two impedances 
Z
1
=
6

j

and 
Z
2
=
8
-
j

are in series and the whole combination is in 
parallel with a third impedance 
Z
3
 
=
5

j

. The circuit is driven by a sinusoidal current source 
i
S
(t
=
10 cos(120
p
t
-
30
°
) A. (i) Solve the circuit by phasor diagram method (ii) Find the complex 
power delivered to the three impedances. (iii) Verify the conservation of active power and reactive 
power in the circuit.
40. The star–delta transformation equation developed for resistive circuits is applicable to impedances 
in phasor equivalent circuits. Apply star–delta transformation and obtain the complex power 
delivered to the 
Z
in the circuit in Fig. 7.12-11 
10 

10 – 
j
10 

10 + 
j
10 

5 + 
j


– 
j
20 

Z
+

25
V rms

Fig. 7.12-11 
41. A 230 V rms, 50 Hz distribution line feeds power to a load located at the far end of the line. The 
line can be modelled by a series combination of 0.07 

resistance and 0.3 

inductive reactance. 
The load is represented by impedance of 15

j15 

. (i) Obtain the load voltage and line current 
by phasor diagram method. (ii) Calculate the source complex power, source power factor and load 
complex power and transmission efficiency. 
42. A 110 V rms, 60 Hz distribution line feeds power to a load located at the far end of the line. The 
line can be modelled by a series combination of 0.05 

resistance and 0.2 

inductive reactance. 
The load is represented by impedance of 5

j10 

. (i) Obtain the load voltage and line current. 
(ii) Find the capacitance value of a capacitor that should be connected across the load if the 
sending end and receiving end voltage magnitudes are to be 230 V rms. (ii) Calculate the source 
complex power, source power factor and load complex power and transmission efficiency with 
and without the capacitor.


Problems 
7.61
43. If the source delivers 1 kW at unity power factor in the circuit in Fig. 7.12-12 determine the 
impedance 
Z
.
Z
110
V
 
rms
w
10 


j
10 

= 120
π
rad/s
+


45º
Fig. 7.12-12 
44. The current delivered by the source in the circuit in Fig. 7.12-13 is 10 cos(120
p
t – 15
°
) A under 
steady-state condition. The load impedance 

Download 5,69 Mb.

Do'stlaringiz bilan baham:
1   ...   237   238   239   240   241   242   243   244   ...   427




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish