6.Texnologik ishlab chiqarishdagi asosiy jixoz hisobi
Tozalash bo'limining quvvati (kilo/soat) 150000
Absorberdagi bosim (kgf/sm2) 3,0
Gazning dastlabki harorati (0C) 40
Tozalangan gazning harorati (0C) 110
Dietanolamin eritmasining konsentratsiyasi (%) 27
H2S dan kokslangan gazlarni tozalash darajasi (%) 99
Gaz aralashmasidagi H2S ning dastlabki konsentratsiyasi (%) 4.6
Dietanolamin eritmasining yutish qobiliyati (mol/mol) 1,0-1,3
Absorbentning dastlabki harorati 40
Dietanolamin eritmasi va gaz aralashmasining yutilish jarayonidan keyingi harorati (0C) 43
Yutish bosqichiga keladigan gaz aralashmasi ro'yxati
7.1-jadval
Ism
|
Kilo/soat
|
%
|
m3/soat
|
%
|
H2
|
102.1212
|
1.0
|
1244.65
|
16.33
|
CH4
|
123.85
|
13.8
|
2147.02
|
28.17
|
C2H6
|
822.357
|
7.4
|
614.03
|
8.06
|
C3H8
|
2533,75
|
22.8
|
1289.91
|
16.93
|
C4H10
|
3278.3173
|
29.5
|
1266.11
|
16.61
|
C5H12
|
2322.6
|
20.9
|
722.59
|
9.48
|
H2S
|
511.195
|
4.6
|
336,79
|
4.42
|
Umumiy hisob
|
150000
|
100
|
7621.1
|
100
|
Hisoblash:
Xarajat:
1. Gaz aralashmasi bilan kirib kelayotgan H2S ning 99% yutuvchi hujayrada yutiladi. Yutilgan vodorod sulfidi miqdorini aniqlash
511,195*99/100=506,083 kilo/soat;
2. Gaz aralashmasida qolgan vodorod sulfid miqdorini aniqlash
511,195-506,083=5,112 kilo/soat
25-35 m.% dietanolamin eritmasining singdirish qobiliyati 1,0-1,3 mol/mol. Biz o'rtacha 1,15 ni olamiz.
506,083/34=14,88479 kmol/soat;
14,88479*MDEA+H2O/1,15=14,88479*23.18734/1,15=300,121 kg/soat
MMEA+H2O = (27 + 73) / (27/105 + 73/18) = 23,187 g/mol
4. Yutish jarayonidan keyin aralashmaning miqdorini aniqlash:
300.121+506,083=806,2 kilogramm/soat
Absorbsiyaning moddiy balansi:
Kelyapti
|
Xarajatlar
|
Ism
|
Kilo/soat
|
%
|
Ism
|
Kilo/soat
|
%
|
H2
|
111.1294
|
1.0
|
H2
|
111.1294
|
1.05
|
CH4
|
1533.58572
|
13.8
|
CH4
|
1533.58572
|
14.46
|
C2H6
|
822.35756
|
7.4
|
C2H6
|
822.35756
|
7.75
|
C3H8
|
2533,75
|
22.8
|
C3H8
|
2533,75
|
23.89
|
C4H10
|
3278.3173
|
29.5
|
C4H10
|
3278.3173
|
30.91
|
C5H12
|
2322.6
|
20.9
|
C5H12
|
2322.6
|
21.9
|
H2S
|
511.195
|
4.6
|
H2S
|
5.112
|
0,0482
|
Umumiy hisob
|
150000
|
100
|
Umumiy hisob
|
149606.852
|
100
|
R2NH
|
300.121
|
2.63
|
R2NH+H2S
|
806.2
|
7.064
|
Umumiy hisob
|
11413.06
|
100
|
Umumiy hisob
|
11413.06
|
100
|
Yutish jarayonining issiqlik hisobi
Issiqlik kelishi:
Vodorod bilan birga keladigan issiqlik miqdori
Q1 = G ∙ c ∙ t =150000 ∙14,32 ∙ 40 = 85920,92 kJ/soat
Issiqlik miqdori metan bilan birga keladi
Q2 =1533,58572 ∙ 2,22 ∙ 40 = 136182,412 kJ/soat
Etan bilan birga keladigan issiqlik miqdori
Q3 =822,35756 ∙ 1,75 ∙ 40 = 57565,03 kJ/soat
Issiqlik miqdori propan bilan birga keladi
Q4 =2533,75 ∙ 1,67 ∙ 40 = 169254,5 kJ/soat
Butan bilan birga keladigan issiqlik miqdori
Q5 =3278,3173 ∙ 1,67 ∙ 40 = 218991,6 kJ/soat
Vodorod sulfidi bilan birga keladigan issiqlik miqdori
Q6 =511,195 ∙ 1,013 ∙ 40 = 20713,62 kJ/soat
Pentan bilan birga keladigan issiqlik miqdori
Q7 =2322,6∙ 1,6 ∙ 40 = 148646,4 kJ/soat
DEA eritmasi bilan birga keladigan issiqlik miqdori
Q8 =300.121∙ 5,07155∙ 40 = 60883,2 kJ/soat
9. Yutish jarayonining issiqlik miqdori:
Q9 =506.083∙ 141,1 = 71408,3113 kJ/soat
Bu erda: 141,1 -Suvli dietanolamin eritmasida vodorod sulfidining yutilish entalpiyasi (27%) (kJ/kg).
10. Kelayotgan issiqlikning umumiy miqdori.
Qto = Q1 + Q2 + Q3 + Q4 + Q5 + Q6 + Q7 + Q8 + Q9 = 63654,92+ +136182,412+57565,03+169254,5+218991,6+20713,62+148646,4+06.
+ 71408.3113 = 947300 kJ/soat
Issiqlik sarfi:
Vodorod bilan ajralib chiqadigan issiqlik miqdori
Q'1 = G ∙ c ∙ t =150000∙14,32 ∙ 43 = 68429,04 kJ/soat
Metan bilan chiqadigan issiqlik miqdori
Q'2 =1533,58572 ∙ 2,22 ∙ 43 = 146396,09 kJ/soat
Etan bilan chiqadigan issiqlik miqdori
Q'3 =822,35756 ∙ 1,75 ∙ 43 = 61882,406 kJ/soat
Propan bilan chiqadigan issiqlik miqdori
Q'4 =2533,75 ∙ 1,67 ∙ 43 = 181948,59 kJ/soat
Butan bilan qoladigan issiqlik miqdori
Q'5 =3278,3173 ∙ 1,67 ∙ 43 = 235415,9653 kJ/soat
Vodorod sulfidi bilan ajralib chiqadigan issiqlik miqdori
Q'6 =5,112 ∙ 1,013 ∙ 43 = 222,674 kJ/soat
Pentan bilan qoladigan issiqlik miqdori
Q'7 =2322,6∙ 1,6 ∙ 43 = 159794,88 kJ/soat
DEA eritmasi bilan chiqadigan issiqlik miqdori (H2S ishtirokida)
Q'8 =806.2∙ 2,3 ∙ 43 = 79733,18 kJ/soat
Qolgan issiqlikning umumiy miqdori.
Q'to = Q'1 + Q'2 + Q'3 + Q'4 + Q'5 + Q'6 + Q'7 + Q'8= 68429,04 + +146396,09+61882,406+181948,59+235415,9653+222,679+18. +
+79733,18 = 933822,824 kJ/soat
10. Atrof-muhitga yo'qolgan issiqlik miqdori.
Qlost = 947300 – 933822,824 = 13477,18 kJ/soat
7.2. Asosiy qurilmani hisoblash
O'rnatish
|
Eshik ichida - tashqarida
|
Suyuqlikning xarakteristikasi
|
H2, Hc, H2O, AMIN SUYUQ + GAZ
|
Zilzila omili
|
0.2
|
Shamol pressi
|
kg/m3
|
38.8
|
Dizayn matbuoti
|
MPaG
(kg/sm2G)
|
0,5+FV
|
Dizayn harorati
|
0C
|
120
|
Ish bosimi
|
MPa
|
0,2 – 0,55
|
Ishlash harorati
|
0C
|
38/41
|
Radiografiya
| |
100%
|
Payvandlashdan keyingi issiqlik bilan ishlov berish
| |
Ha
|
Birgalikda samaradorlik
| |
1
|
Korroziyaga qarshi ruxsat
|
Mm
|
3
|
Gidro. Sinov tugmasini bosing.
|
MPaG (kg/sm2G)
|
9.4
|
Pnevmo. Sinov tugmasini bosing.
|
MPaG (kg/sm2G)
|
0,05
|
7.2.1. Gaz bug'ining tezligini va absorber diametrini aniqlash:
Gaz oqimining tezligi quyidagi formula bo'yicha aniqlanadi (klapanli bosqichli absorberlar (plastinkalar) uchun):
Kelayotgan gazlarning o'rtacha molekulyar massasi:
Mening=2*0,1633 + 16*0,2817 + 30*0,0806 + 44*0,1693 + 58*0,1661 + +72*0,0948 +34*0,0442 = 32,6632 g/mol.
Absorberga keladigan gazlarning umumiy miqdori: kmol/soat
vbi=7621,1/22,4=150000/32,6632=340,23 kmol/soat
Gaz zichligi:
=MP273/(22,4T'P0) = 32,6632*0,2*106*273/(22,4*(273+40)*0,1*106) = =2,54366 kg/m3.
40 0C da suyuqlik (boyitilgan changni yutish) zichligi: 970 kg/m3
Gaz tezligi Sauders va Braun tenglamalari bilan aniqlanadi:
Vg=1,2*0,305*c* =1,2*0,305*670*=12165 kg/(m2*soat)
Qachonki bosqichlar orasidagi masofalar hs=500mm c=670.
Absorberning diametri:
Da= = = 1,07876 m .
Standart bo'yicha Da=1150 mm=1,15 m ni olamiz.
7.2.2. Absorbentning oqim tezligini hisoblash:
25-35 m.% dietanolamin eritmasining singdirish qobiliyati 1,0-1,3 mol/mol. Biz o'rtacha 1,15 ni olamiz.
506,083/34=14,88479 kmol/soat;
14,88479*MDEA+H2O/1,15=14,88479*23.18734/1,15=300,121 kg/soat
Uskunaning balandligini aniqlash:
HA=H1+H2+H3;
Bu erda: H1 - yuqori so'rilish bosqichi (plastinka) ustidagi balandlik.
H2 - pog'onalar (plitalar) bilan bog'langan absorber qismining balandligi.
H3 - pastki yutish bosqichidan past balandlik (plastinka)
H1 = 1,8*Hs;
Bu erda: Hs-bir pog'ona (plastinka) orasidagi masofa=0,9 m.
Qatlamlar (plitalar) bilan bog'langan absorber qismining balandligi:
H2 = (n – 1)*Hs=(20-1)*0,5=9,5
H3 absorberining pastki qismi balandligi 3,870 metrga moslashtirilgan.
H3 absorberining pastki qismi balandligi 3,870 metrga moslashtirilgan.
HA = 0,9 + 9,5 + 3,870 =14,27 m
Asbobning beton asosi va bosh qismining balandligi standart 5500 mm va 690 mm (diametrga qarab) olinadi.
7.2.3. Vana plitalarini konstruktiv loyihalash elementlari.
Qopqoq plitasining diametri absorberning ichki diametridan 30 mm kamroq. Plita rulman halqasiga o'rnatiladi. Qopqoq elementlari teng qirrali uchburchakning tepasiga qo'yiladi, ulardan biri quyilish chizig'iga va qabul qiluvchi suyuqlikka majburiy parallel (chizmaga qarang):
Bir diapazonda elementlarning qadami 100 mm va 87 mm oralig'ida;
To'kish chizig'ining uzunligi LL = 0,75 * DA = 0,75 * 1150 = 862,5 mm;
Ushbu turdagi plastinkada 74 (8.6252) valf elementlarini joylashtirish mumkin. Indekslangan o'lchamdagi valf elementining sxemasi chizmada keltirilgan. Vertikal plastinka sifatida bajarilishi mumkin bo'lgan hpo o'zaro faoliyat devorining balandligi (chizmaga qarang) 25 dan 50 mm gacha. Biz hpo = 37 mm ni moslashtira olamiz.
Do'stlaringiz bilan baham: |