particle volume fraction
19
Figure 2.3
Modes of energy transport in nanofluid
23
Figure 2.4
Hysteresis observed on viscosity for alumina (47 nm, 7%)-
water nanofluid
28
Figure 2.5
Nanofluid viscosity vs. temperature for low volume fraction of
nanoparticles
29
Figure 2.6
The relative viscosity as a function of temperature in water
based alumina nanofluids
31
Figure 2.7
Schematic of experimental setup to measure heat transfer and
pressure drop of nanofluid
32
Figure 2.8
Schematic of experimental setup for convective heat transfer
and viscous pressure drop measurement
35
viii
Figure 2.9
Schematic of experimental setup for measuring pressure drop
and heat transfer
39
Figure 3.1
TC 550MX constant temperature bath
43
Figure 3.2
DV II + Pro Extra Brookfield viscometer connected to the TC-
550MX temperature bath
45
Figure 3.3
Schematic of thermal conductivity measurement using the KD2
Pro thermal property analyzer
47
Figure 3.4
Schematic of experimental loop for conducting pressure drop
and heat transfer measurements
50
Figure 3.5
Flow loop reservoir
52
Figure 3.6
Liquiflow sealed gear pump
53
Figure 3.7
Micro Motion mass flow sensor connected to a 1700R
transmitter
54
Figure 3.8
Three Rosemount pressure transmitters (model 3051)
connected in parallel
55
Figure 3.9
Agilent data acquisition unit (model 34972A)
56
Figure 3.10
Thermocouple wire tip cemented to the test section outer wall
with the help of Omega bond cement
57
Figure 3.11
N5761A Agilent DC power supply unit
58
Figure 3.12
304 Hypodermic tubing of 6 gauge, 0.203 inches OD, 0.183
inches ID and 36 inches length.
59
Figure 3.13
304 Hypodermic tubing of 10 gauge, 0.134 inches OD, 0.118
inches ID and 36 inches length.
60
ix
Figure 3.14
304 Hypodermic tubing of 10 gauge, 0.134 inches OD, 0.118
inches ID and 18 inches length
60
Figure 3.15
Thermal conductivity measurement for a standard calibration
fluid at a temperature of 20°C
62
Figure 3.16
Ameterk hand pump for calibration of the pressure transducers
63
Figure 3.17
Calibration graph for 0–9 psi pressure transmitter
64
Figure 3.18.
Calibration graph for 0–36 psi pressure transmitter
64
Figure 3.19
Calibration graph for 0–300 psi pressure transmitter
65
Figure 3.20
Viscosity vs. temperature curve for the given standard viscosity
fluid (The fluid has a viscosity of 493 cP at 25°C)
66
Figure 3.21
RTD readings vs. thermocouple readings for the TT-T-36-SLE-
1000 thermocouple
67
Figure 3.22
RTD readings vs. thermocouple readings for the TMQSS-0.0U-
6 thermocouple
68
Figure 3.23
Stainless steel thermal conductivity vs. temperature, Ho et al.
(1977)
75
Figure 4.1
Comparison between measured value of thermal conductivity
for distilled water at temperature range from 7°C t0 50°C with
the standard value
78
Figure 4.2
Plot between the measured friction factor of water in different
tube diameter vs. the Reynolds number
81
Figure 4.3
Comparison of the measured friction factor of water in different
tube diameter with the value of friction factor calculated from
the Blasius (1913) correlation
82
x
Figure 4.4
Comparison of the measured friction factor of water in different
tube diameter with the value of friction factor calculated from
the Bhatti and Shah (1987) correlation
83
Figure 4.5
Comparison of the measured friction factor of water in different
tube diameter with the value of friction factor calculated from
the Drew et al. (1932) correlation
83
Figure 4.6
Comparison of the measured friction factor of water in different
tube diameter with the value of friction factor calculated from
the Churchill (1977) correlation
84
Figure 4.7
Measured Nusselt number vs. Reynolds number for water
flowing in different tubes
87
Figure 4.8
Plot showing comparison of the measured Nusselt number and
the Nusselt number given by the Dittus and Boelter correlation
for the 0.175 inch ID tube
88
Figure 4.9
Plot showing comparison of the measured Nusselt number and
the Nusselt number given by the Gnielinski correlation for the
0.175 inch ID tube.
89
Figure 4.10
Plot showing comparison of the measured Nusselt number and
the Nusselt number given by the Dittus and Boelter correlation
for the 0.118 inch ID, 36 inch long tube
89
Figure 4.11
Plot showing comparison of the measured Nusselt number and
the Nusselt number given by the Gnielinski correlation for the
0.118 inch ID, 36 inch long tube
90
Figure 4.12
Plot showing comparison of the measured Nusselt number and
the Nusselt number given by the Dittus and Boelter correlation
for the 0.118 inch ID, 18 inch long tube
90
Figure 4.13
Plot showing comparison of the measured Nusselt number and
the Nusselt number given by the Gnielinski (1976) correlation
for the 0.118 inch ID, 18 inch long tube
91
xi
Figure 4.14
Plot showing the thermal conductivity vs. temperature for water
and NF. A plot for the thermal conductivity ratio vs.
temperature is also shown.
92
Figure 4.15
Plot comparing the values of measured thermal conductivity
ratio and the thermal conductivity ratio given by Maxwell
(1892) equation
94
Figure 4.16
Plot comparing the values of measured thermal conductivity
ratio and the thermal conductivity ratio given by Beck et al.
(2009) equation correlation
95
Figure 4.17
Plot comparing the values of measured thermal conductivity
ratio and the thermal conductivity ratio given by Prasher et al.
(2005) correlation
95
Figure 4.18
Viscosity vs. temperature for water and NF
96
Figure 4.19
Plot showing the viscosity vs. temperature for different
concentration Al
2
O
3
/water nanofluid
97
Figure 4.20
Plot showing the relative viscosity vs. temperature for different
concentration Al
2
O
3
/water nanofluid
98
Figure 4.21
Plot showing the viscosity vs. volume concentration of
nanoparticles for Al2O3/water nanofluid at different
temperatures
99
Figure 4.22
Plot between the shear stress and shear rate for NF
100
Figure 4.23
Plot showing the viscosity vs. temperature for the NF. The NF
is first heated from a temperature of 6°C to30°C and then again
cooled to 6°C
101
Figure 4.24
Plot showing the viscosity vs. temperature for the NF. The NF
is first heated from a temperature of 6°C to 40°C and then
again cooled to 6°C
102
xii
Figure 4.25
Plot showing the viscosity vs. temperature for the NF. The NF
is first heated from a temperature of 6°C to 50°C and then
again cooled to 6°C
102
Figure 4.26
Plot showing the viscosity vs. temperature for the NF. The NF
is first heated from a temperature of 6°C to 60°C and then
again cooled to 6°C
103
Figure 4.27
Plot showing the viscosity vs. temperature for the NF. The NF
is first heated from a temperature of 6°C to 62°C and then
again cooled to 6°C
103
Figure 4.28
Plot showing the viscosity vs. temperature for the NF. The NF
is first heated from a temperature of 6°C to 70°C and then
again cooled to 6°C
104
Figure 4.29
Plot between the friction factor and Reynolds number for the
NF flowing through 0.118 inch ID, 36 inch long tube
105
Figure 4.30
Plot between the friction factor and Reynolds number for the
NF flowing through 0.175 inch ID, 36 inch long tube
105
Figure 4.31
Plot between the Poiseuille number vs. the Reynolds number
for the NF flowing through the 0.175 inch ID, 36 inch long
tube.
106
Figure 4.32
Plot between the Poiseuille number vs. the Reynolds number
for the NF flowing through the 0.118 inch ID, 36 inch long
tube.
106
Figure 4.33
Nusselt number vs.
x
+ for 6% vol. alumina/water nanofluid
flowing through a 0.175 inch ID, 34 inch long heated test
section
109
Figure 4.34
Nusselt number vs.
x
+ for 6% vol. alumina/water nanofluid
flowing through a 0.118 inch ID, 34 inch long heated test
section.
110
xiii
Figure 4.35
Nusselt number vs.
x
+ for 6% vol. alumina/water nanofluid
flowing through a 0.118 inch ID, 18 inch long heated test
section.
111
Figure 5.1
Plot showing the convective heat transfer coefficient vs. gas
mass flow rate for a two phase air-water mixture
115
xiv
LIST OF TABLES
Table
Description
Page
Table 2.1
Model parameters for Al
2
O
3
-water nanofluid
21
Table 2.2
Empirical constants for Al
2
O
3
-water, Hosseini et al. (2010)
26
Table 3.1
Uncertainty in friction factor
73
Table 3.2
Uncertainty in measurement of
Do'stlaringiz bilan baham: |