4.8.3 Run command switching and frequency reference binding

Through F0-27 setting, the three command sources of frequency converter can set their respective frequency source, as shown in the figure above. After the frequency binding channel (corresponding to F0-27) is set for the designated command channel (F0-02), main frequency source X or auxiliary frequency source Y will not take effect, but the given frequency channel defined by F0-27 will be used for determination.


4.8.4 The usage of frequency source given by A1 analog

The frequency source of 580 is given by analog input terminal. 580 control panel is set with 2 analog imputer terminals (AI1, AI2) and the optional I/O expansion card will provide an additional analog input terminal (AI3).

The following examples are given to introduce the specific usage.

1. AI1 voltage input connecting to the potentiometer as frequency source (2V-10V corresponds to 10 Hz -40Hz)



Fig. 4-19 Function code setting of AI1 voltage input frequency reference

2. AI2 current type input connecting to 4DA module of PLC as the frequency source (4-20mA corresponds to 0 Hz -50Hz)

Fig. 4-20 Function code setting of AI2 current type input frequency reference

Notes:

1) 580 control panel is set with 2 analog input terminals (AI1, AI2) and the optional expansion card is set with an additional analog input terminal (AI3).



2) AI1 is 0V~10V voltage type input; AI2 is 0V~10Vvoltage input or 4mA~20mA current input, selected by Jumper J8 on the control panel; AI3 is -10V~10V bipolar voltage signal input.

3) When AI is given as frequency, voltage/current input corresponds to 100.0% setting, which means the percentage of maximum frequency F0-10.

4) The temperature transmitter used for the given analog shall be connected to AI3 terminal of I/O expansion card.

5) Five groups of correspondence curve can be preset for 580 and freely selected by F4-33. The input value and target frequency in each group of curve shall be set by means of function code F4-13 ~F4-27 as well as function code in Group A6.




Download 23,63 Mb.

Do'stlaringiz bilan baham:
1   ...   35   36   37   38   39   40   41   42   ...   63




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish