Copyright 20 13 Dorling Kindersley (India) Pvt. Ltd



Download 5,69 Mb.
Pdf ko'rish
bet272/427
Sana21.11.2022
Hajmi5,69 Mb.
#869982
1   ...   268   269   270   271   272   273   274   275   ...   427
Bog'liq
Electric Circuit Analysis by K. S. Suresh Kumar

V
RN 
=
115

0
°
V rms, 
V
YN
=
115
∠-
110
°
V rms and 
V
BN 
=
132

125
°
V rms delivers power to a balanced delta-connected load with a 
branch-impedance of 23.4

j17.1 
W
through a 3-wire line with a line impedance of 0.2

j0.3 
W

Determine (i) line currents, (ii) line voltages across the load, (iii) active power and reactive power 
delivered by each phase of the source and the three-phase values and (iv) three-phase active power 
and reactive power delivered to the load by using star-delta transformation on load impedance and 
mesh analysis.
24. A delta-connected unbalanced voltage source uses 115

0
°
V rms, 110
∠-
110
°
V rms and 
122

125
°
V in the three branches R–Y, Y–B and B–R, respectively. Each branch source has 1 
W

3 mH inductance in series with it. The frequency of the system is 60 Hz. This source is delivering 
power to an unbalanced delta-connected load that has 10 
W
resistor, 10 
W
resistor in series with 
30 mH inductor and 10 
W
resistor in series with 1000 
m
F capacitor between R–Y, Y–B and B–R, 
respectively. Determine (i) line currents, (ii) source and load branch currents, (iii) line voltages 
across the load, (iv) active power and reactive power delivered by each phase of the source and the 
three-phase values and (v) three-phase active power and reactive power delivered to the load by 
using star-delta transformation on load impedance and mesh analysis.
25. The positive sequence component of line current drawn by a balanced delta-connected load of 
branch impedance 8

j
W
is 20
∠-
30
°
A rms. The negative sequence component of line voltage 


Problems

8.41
across the load is 15
∠-
90
°
V rms. (i) Find the line voltages across the load and line currents. 
(ii) Find the three-phase active power and reactive power delivered to the load from three-phase 
quantities. (iii) Find the three-phase active power and reactive power delivered to the load from 
sequence components.
26. An unbalanced star-connected voltage source delivers power to a balanced star-connected load 
with 8 

j
W
in each phase over a 3-wire impedance-less connection. The load draws a line current 
that has 10

0
°
A rms positive sequence component and 2
∠-
90
°
A negative sequence component. 
The source neutral is earthed solidly and the load neutral is found to be at 10
∠-
150
°
V rms with 
respect to earth. (i) Find the phase voltages and line voltages across the source and load (ii) Find 
the active power and reactive power delivered by the source and delivered to the load.
27. An unbalanced star-connected voltage source delivers power to a balanced star-connected load 
with 7.9

j5.7 
W
in each phase over a 3-wire connection with a wire-impedance of 0.1

j0.3 
W
in 
each wire. The load draws a line current that has 10

0
°
A rms positive sequence component and 
2
∠-
90
°
A rms negative sequence component. The source neutral is earthed solidly and the load 
neutral is found to be at 10

50
°
V rms with respect to earth. (i) Find the phase voltages and line 
voltages across the source and load (ii) Find the active power and reactive power delivered by the 
source and delivered to the load.
28. An unbalanced star-connected voltage source delivers power to a balanced star-connected load 
with 7.9

j5.7 
W
in each phase over a 4-wire connection with a wire-impedance of 0.1

j0.3 
W
in 
each wire. The load draws a line current that has 10

0
°
A rms positive sequence component and 
2
∠-
90
°
A rms negative sequence component. The neutral return current is found to be at 1.5
∠-
100
°
A rms. (i) Find the phase voltages and line voltages across the source and load (ii) Find the 
active power and reactive power delivered by the source and delivered to the load.
29. The magnitudes of line voltages at a certain point in a three-phase system are measured as 400 V 
rms, 380 V rms and 410 V rms between R–Y, Y–B and B–R, respectively. Find the symmetrical 
components of the line voltage. [Hint: The equation 

Download 5,69 Mb.

Do'stlaringiz bilan baham:
1   ...   268   269   270   271   272   273   274   275   ...   427




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish