1. Three voltage phasors 100

0
°
V, 100
∠-
120
°
V and 110

120
°
V cannot be the line voltages of a 
three-phase source. Explain why.
2. The line currents flowing into a load are found to be 10
∠-
90
°
A, 10
∠-
200
°
A and 10

30
°
A. 
Explain why the load cannot be a delta-connected one.
3. The line currents flowing into a load are found to be 10
∠-
30
°
A, 10
∠-
150
°
A and 9

90
°
A. 
Show that the three-phase system has to be a 4-wire system and that the load has to be star- 
connected.
4. The line currents flowing into a load from a balanced supply are found to be 10

0
°
A, 5

2

-
135
°
A and 5

2

135
°
A. Is it possible to decide whether the load is delta-connected or star 
connected from this data? 
5. The phase-voltage phasors of a Y-connected three-phase voltage source are 100

0
°
V, 100
∠-
90
°
V and 100

90
°
V. Calculate the line voltages and explain why line voltage magnitude is not equal 
to 100

3 V.
6. Three sinusoidal current sources 10

0
°
A, 10
∠-
120
°
A and 8

120
°
A are used to form a three-
phase 3-wire current source. Explain why this current source has to be a delta-connected one.


8.38


SinusoidalSteady-StateinThree-PhaseCircuits
7. A balanced three-phase voltage source of 400 V, 50 Hz delivers 10 A at unity power factor to 
a balanced three-phase load through a connection impedance of 1

j
W
. Is the line voltage 
magnitude across the load equal to 400 V – 10 V 
=
390 V? If not, why and what is the correct 
value?
8. Find the symmetrical components of a set of three currents 10
∠-
35
°
A, 10
∠-
35
°
A and 10
∠-
35
°
A.
9. An electrodynamometer type wattmeter is a measuring instrument that measures average power. 
It has two coils called current coil and pressure coil. The current coil terminals are usually marked 
M and L and the pressure coil terminals are usually marked V and COM. The meter measures 
the average of the product v(t)
× 
i(t) where v(t) is the voltage of COM with respect to V and i(t
is the current flowing from M to L in the meter. In the case of sinusoidal steady-state, the meter 
measures V
rms 
I
rms
cos
f
where V
rms 
is the rms value of voltage applied across pressure coil, I
rms 
is 
the rms value of current flowing through current coil and 
f
is the angle between these two phasors. 
Two such wattmeters can be used to measure active power in a three-wire system irrespective of 
the nature of source and load connections (i.e., star or delta). The wattmeter connection to do this 
is shown in Fig. 8.7-1. 
WM
M
R
R
Y
Y
B
B
M
L
L
COM
COM
+
+
+
+




V
WM

Download 5,69 Mb.

Do'stlaringiz bilan baham:
1   ...   263   264   265   266   267   268   269   270   ...   427




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish