8. Perform security sequence. Send a DisableNormalCommunication request message, verify positive 
response. Begin TesterPresent message periodic. Enable programming mode with the $A5 service. Send 
RequestDownload message with a valid dataFormatIdentifier and an invalid unCompressedMemorySize 
parameter value. Verify proper negative response reject message ($7F $34 $12, sub-function not 
supported) is sent. 
9. With the manufacturers enable counter > $00 or vulnerability flag = $FF and security has not been 
accessed (SecurityAccess ($27) request has not been sent),
 
send a DisableNormalCommunication 
request message, verify positive response. Begin TesterPresent message periodic. Enable programming 
mode with the $A5 service. Send RequestDownload message with a valid dataFormatIdentifier and 
unCompressedMemorySize parameter value. Verify that negative response message ($7F $34 $22, 
conditions not correct) is sent (because security has not been accessed). 
10. With the manufacturers enable counter > $00 or vulnerability flag = $FF, perform security sequence. Send 
a DisableNormalCommunication request message, verify positive response. Begin TesterPresent 
message periodic. Enable programming mode with the $A5 service. Send RequestDownload message 
with a valid dataFormatIdentifier and unCompressedMemorySize parameter value. Verify positive 
response message. 
Procedure 3: 
(If negative response code $78 is supported by the ECU). 
1. Perform security sequence. Send a DisableNormalCommunication request message, verify positive 
response. Begin TesterPresent message periodic. Enable programming mode with the $A5 service. 
Create the conditions under which the ECU should return a $7F $34 $78 response and send a valid 
request for this service. Verify that proper response is sent. 
2. Repeat previous step of this procedure for each possible reason an ECU would send the negative 
response with response code $78. 

Download 8,35 Mb.

Do'stlaringiz bilan baham:
1   ...   198   199   200   201   202   203   204   205   ...   406




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish