14.10
Magnetically Coupled Circuits
K
I
1
(A rms)
I
2
(A rms)
P
10
W
(W)
P
40
W
(W)
PF
Z
in
(
W
)
0
3.714
∠-
68.2
°
0
137.94
0
0.371
10
+
j25
0.1
3.74
∠-
67.86
°
0.174
∠-
46
°
139.65
1.21
0.376
10.09
+
j24.78
0.5
4.334
∠-
58.2
°
1.006
∠-
36.4
°
187.83
40.48
0.527
12.16
+
j19.61
1
5.281
∠-
10.49
°
2.451
∠
11.31
°
278.89
240.29
0.983
18.62
+
j 3.45i
(b) We observe from the table of results that as the coupling coefficient increases (i) the primary
and secondary currents increase in magnitude and become more active
in content than reactive,
(ii) power delivered to the resistor in the secondary side increases, (iii) the power factor of circuit
increases and (iv) the source experiences a decreasing input impedance that becomes more and more
resistive.
Now, we raise the self-inductance level of the coils by 1000 fold. But we keep the ratio between
them at 4 as before. The mesh equations for
k
=
1 are
10
25 10
50 10
50 10
40
10
100 0
3
3
3
5
1
2
+
×
−
×
−
×
+
=
∠ °
j
j
j
j
I
I
00
We observe that the reactive terms in the matrix entries overpower the resistive terms. The solution
is obtained as
I
1
=
5
∠-
0.01
°
A rms and
I
2
=
2.5
∠
0.01
°
A rms.
Average power dissipated in 10
W
resistor is 5
2
×
10
=
250 W
Average power dissipated in 40
W
resistor is 2.5
2
×
40
=
250 W
Average power delivered by source
=
100
×
5
×
cos0.01
°
=
500 W.
Impedance seen by source
=
Z
in
=
100
∠
0
°
÷
5
∠-
0.01
°
=
20
+
j0.004
W
The input impedance as seen by the source is almost purely resistive at 20
W
. The resistor that is in
series with the source in the primary side must be contributing 10
W
to the input impedance. Therefore,
the transformer and its secondary load of 40
W
resistor contributes 10
W
to input impedance. Thus, the
equivalent impedance of the transformer plus 40
W
load seems to be an almost pure resistance of 10
W
. The ratio between 10
W
and 40
W
happens to coincide with the ratio
L
1
:
L
2
– that is a coincidence
that calls for further analysis.
Let us calculate the voltage appearing across primary and secondary windings of the transformer.
Voltage across primary winding
=
100
∠
0
°
-
10
×
5
∠-
0.01
°
≈
50
∠
0
°
V rms
Voltage across primary winding
=
40
×
2.5
∠
0.01
°
≈
100
∠
0
°
V rms
Thus, primary voltage: secondary voltage
≈
1:2
=
L
L
1
2
:
and using the solution for currents,
primary current: secondary current
≈
2:1
=
L
L
2
1
:
. That makes it too many coincidences to pass
over lightly. Therefore, we analyse the transformer with
k
=
1 in greater detail now.
14.3
the Perfectly couPled tranSforMer and the Ideal tranSforMer
Figure 14.3-1 shows a two-winding transformer with primary self-inductance of
L
1
and secondary
self-inductance of
L
2
with coupling coefficient of unity. We neglect
the winding resistance
for the time being. The two circuits shown in this figure differ only in the
dot polarity in the
transformer.
The Perfectly Coupled Transformer and The Ideal Transformer
14.11
+
–
+
k
= 1
(a)
–
+
–
I
S
I
p
v
p
v
s
Z
L
L
1
L
2
+
–
(b)
k
= 1
I
S
I
p
+
–
v
p
L
1
+
–
v
s
Z
L
L
2
Fig. 14.3-1
A passively terminated two-winding transformer with
k
=
1
The primary is driven by a source
=
2
V
t
cos
w
V and secondary is
passively terminated in an
impedance Z
L
=
R
L
+
j X
L
W
. Passive termination implies that there are no sources of any kind in the
load circuit.
The mesh currents are
I
p
and
I
s
themselves and the mesh equations for circuit in Fig. 14.3-1 (a) in
matrix form are
j L
j M
j M
Z
j L
I
I
V
p
s
w
w
w
w
1
2
0
0
−
−
+
=
∠ °
L
Since
k
=
1, the value of
M
=
L L
1 2
. Solving for primary and secondary current phasors using this
value for
M, we get
I
V
j L
L
L
V
Z
V
j L
L
L Z
I
V
L
L
p
p
s
=
∠
+
∠
=
+
= ∠
0
0
1
1
0
1
2
1
1
2
1
2
1
w
w
L
L
=
=
=
∴
=
1
1
2
1
2
1
2
1
Z
V
L
L
Z
V
I Z
V
L
L
V
V
L
L
p
s
s
p
s
p
L
L
L
We have used the fact that the source voltage phasor
V
∠
0
°
itself is the primary voltage phasor
V
p
to make substitutions in the equation above.
We note that the secondary voltage and primary voltage are in phase and related by a real scaling
factor of
L
L
2
1
. However,
this number is nothing but
n
n
2
1
, where
n
1
and
n
2
are the number of turns
employed in primary and secondary windings. This is so since self-inductance of a coil is proportional
to the square of the number of turns in the coil. We represent this ratio as
turns ratio ‘n’.
Therefore, secondary voltage magnitude in a transformer with unity coupling coefficient
is turns ratio times the primary voltage magnitude.
The equation for
I
p
is the sum of two terms. Each term involves a division of primary voltage phasor
by impedance. Therefore, the equation for
I
p
suggests that the input impedance of the circuit is a parallel
combination of two impedances – an inductor of
L
1
and another impedance of value
L
L
Z
Z
n
L
1
2
2
L
=
.
14.12
Magnetically Coupled Circuits
Therefore, a transformer with unity coupling coefficient
reflects
the
secondary load
impedance
Z
L
onto the primary side as a
turns-ratio transformed impedance
of value
Z
L
/
n
2
where
n
=
secondary turns/primary turns.
Thus, the entire transformer and load circuit can be replaced by the equivalent circuit shown in Fig.
14.3-2 as far as the input side
v–i behaviour under sinusoidal steady-state condition is concerned. We
will see later that this is true not only for sinusoidal steady-
state analysis but also for time-domain analysis too.
The primary winding resistance is included as a series
resistance in the primary side, whereas the secondary
winding resistance is included as a part of
R
L
in the load
for analysis purposes.
Now, we consider the circuit in Fig. 14.3-1 (b). Reader
may easily verify that the mesh equations for this circuit
will be,
j L
j M
j M
Z
j L
I
I
V
p
s
w
w
w
w
1
2
0
0
L
+
=
∠ °
Both the off-diagonal terms in the mesh impedance matrix have changed sign. The solution for
primary and secondary current phasors with
k
=
1 will be,
I
V
j L
L
L
V
Z
V
j L
L
L Z
V
j L
n
p
p
p
=
∠
+
∠
=
+
=
+
0
0
1
1
1
1
2
1
1
2
1
1
w
w
w
L
L
22
2
1
2
1
0
1
1
Z
I
V
L
L
Z
nV
Z
V
I Z
V
L
L
s
p
s
s
p
L
L
L
L
= − ∠
= −
=
= −
= −
nV
p
There is no difference in solution
except for 180
°
phase shift in secondary voltage. That is anyway
expected due to the change in relative polarity of windings. The voltage magnitude ratio remains at
turns ratio
n.
But the most important aspect to be noted is that the same equivalent circuit shown in Fig. 14.3-2
will describe the transformer in this case too. See the equation for primary current phasor. In fact, this
is
true even if k
≠
1.
The input impedance of a passively terminated transformer is independent of its
dot
point assignment.
There are many important applications of transformers with
k
≈
1 in which we make use of the
inductor
L
1
that appears in the input impedance to advantage. A tuned amplifier widely employed in
communication circuits is such an application example.
There are many applications of transformers with
k
≈
1 in electrical power engineering and
electronics engineering where that inductance in the input impedance of transformer is not desirable.
Fig. 14.3-2
Input equivalent
circuit of transformer
with
k
=
1
Do'stlaringiz bilan baham: