ReportProgrammedState ($A2)
with 
the AllNodes CANId and AllNodes extended address (finalization of the diagnostic configuration 
matrix - on each link as needed). 

Each SPS programmable ECU shall respond. 

SPS_TYPE_A and SPS_TYPE_B ECUs respond with their permanent diagnostic USDT 
response CANId (which falls within the reserved range of diagnostic response CAN Identifiers). 

An SPS_TYPE_C ECU responds with the SPS_PrimeRsp CANId ($3xx where xx = diagnostic 
address). 

At this point the SPS_TYPE_C ECU would activate and accept the SPS_PrimeReq ($0xx) 
CANId as a diagnostic PTP request CANId (where xx = diagnostic address). 

MSSC ECUs shall only respond to the $A2 service on the subnet where they support 
programming (MSSC ECUs shall only be programmable on one subnet 
– see 4.3.4. 

Retrieve necessary ECU ID and vehicle option content (e.g., engine type) information from the 
programmable node(s) (using 
ReadDataByIdentifier ($1A)
service). 

Use the SPS_PrimeReq ($0xx) diagnostic request CANId for each SPS_TYPE_C ECU targeted. 

Use USDT permanent diagnostic request CANId (determined based on offset from response 
CANId received) for SPS_TYPE_A and SPS_TYPE_B ECUs. 

Use information received via the previously executed service ReportProgrammedState ($A2) to 
identify all SPS programmable ECUs. 

Retrieve seed of programmable module(s) using the 
SecurityAccess ($27)
service. 

Security may not be implemented in all ECUs that are SPS programmable. The SecurityAccess 
service is required for all SPS programmable ECUs that are Emission, Safety, or Theft related. 

optional 
step 
Send a 
ReturnToNormalMode ($20)
request (with AllNodes CANId and AllNodes extended 
address - on each link as needed).

This request transitions all subnets back to normal operation while the tool is retrieving 
information from the SPS database. This step is optional since a P3
C
timeout would occur after 
the tester is disconnected and this shall also cause all nodes on all subnets to revert back to 
normal operation. 
10 
Disconnect tester. 
CameraLoops.com



Download 8,35 Mb.

Do'stlaringiz bilan baham:
1   ...   335   336   337   338   339   340   341   342   ...   406




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish