8.11.1 Service Description. 
The DefinePIDbyAddress service allows a tester to dynamically assign an ECU 
variable to a PID via the address of the variable. The resulting PID data can then be read using either the $22 
service or the $AA service. The service is intended to be used to retrieve RAM variables. Calibrations and 
unprotected areas of EEPROM/Flash memory should not be packed into a dynamic PID. This type of data is 
static in nature and can be obtained using service $23. 
The dynamic PID being defined is identified by parameterIdentifier (PID), memoryAddress (MA) and 
memorySize (MS). The size of parameterIdentifier is fixed at two bytes; the size of the memoryAddress 
parameter in the request message can be two, three, or four bytes in length depending on the ECU internal 
addressing scheme. The number of bytes that a tester shall use in the memoryAddress portion of the request 
message for a given ECU shall be documented in the appropriate CTS, SSTS, or supplemental diagnostic 
specification referenced by either of the preceding documents. The memorySize parameter in the request 
message can range from one to seven bytes. (Seven bytes is the maximum in order to allow the PID to be part 
of a DPID.) 
The DefinePIDbyAddress positive response message includes the parameterIdentifier (PID), specified in 
request message. 
A device may deny access to specific addresses in order to protect their operating system and other secure 
data. An ECU may also restrict the testers ability to read specific addresses based on the security status of the 
ECU. If any of the addresses (that fall in the range of the request message) have security restrictions then the 
request shall be rejected unless the tester had previously successfully accessed security. 
Note: 
Security access is only required if the ECU is locked based on the status of the MEC and/or the 
vulnerability flag see the SecurityAccess ($27) service for more information. 
The range of PIDs that can be dynamically defined by this service in a given ECU shall be documented in the 
appropriate CTS, SSTS, or supplemental diagnostic specification referenced by either of the preceding 
documents. 
Note:
If a tool requests a dynamic PID before this service is called to define the PID then the resulting 
response is undefined. 
CameraLoops.com



Download 8,35 Mb.

Do'stlaringiz bilan baham:
1   ...   182   183   184   185   186   187   188   189   ...   406




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish