Table 1.
Data of well.
V, t/day
9.5
11.2
12.5
14.5
17
20
23
25
Q, 10
3
m
3
/day
38
51
62
64
66
65
62
58.5
1. For identification of gas lift wells, different scientific
approaches
were
developed:
parabolic
identification,
logarithmic parabolic identification and etc. But the most
useful for efficiently representation among them is logarithmic-
parabolic identification that we can see by using R-square.
2. Optimal regime of gas-lift well is defined by the interval
between optimum point (V, Q) and maximum point (
̅, ̅).
This interval is important for effectively working of well. If we
inject gas out of this interval, we will get low production of oil.
Do'stlaringiz bilan baham: |