Vari-ant
|
Tipi
|
Pн
kVt
|
nн,
ayl/min
|
ηн
|
cosφн
|
|
Mmin/Mн
|
Mmax /Mн
|
1
|
4A80A2УЗ
|
1,5
|
2875
|
0,81
|
0,85
|
2,1
|
1,4
|
2,6
|
2
|
4A90L2УЗ
|
3,0
|
2870
|
0,845
|
0,88
|
2,1
|
1,6
|
2,5
|
3
|
4A100S2УЗ
|
4,0
|
2900
|
0,865
|
0,89
|
2,0
|
1,6
|
2,5
|
4
|
4A100L2УЗ
|
5,5
|
2890
|
0,875
|
0,91
|
2,0
|
1,6
|
2,5
|
5
|
4A112M2УЗ
|
7,5
|
2925
|
0,875
|
0,88
|
2,0
|
1,8
|
2,8
|
6
|
4A132M4УЗ
|
11,0
|
1460
|
0,875
|
0,87
|
2,2
|
1,7
|
3,0
|
7
|
4A160S4УЗ
|
15,0
|
1465
|
0,885
|
0,88
|
1,4
|
1,0
|
2,3
|
8
|
4A160M4УЗ
|
18,5
|
1470
|
0,895
|
0,88
|
1,4
|
1,0
|
2,3
|
9
|
4A180S4УЗ
|
22,0
|
1470
|
0,90
|
0,90
|
1,4
|
1,0
|
2,3
|
10
|
4A180M4УЗ
|
30,0
|
1475
|
0,91
|
0,89
|
1,4
|
1,0
|
2,3
|
11
|
4A225M6УЗ
|
37,0
|
975
|
0,915
|
0,89
|
1,2
|
1,0
|
2,3
|
12
|
4A250S6УЗ
|
45,0
|
980
|
0,915
|
0,89
|
1,2
|
1,0
|
2,1
|
13
|
4A250M6УЗ
|
55,0
|
985
|
0,915
|
0,89
|
1,2
|
1,0
|
2,1
|
14
|
4A280S6УЗ
|
75,0
|
980
|
0,925
|
0,89
|
1,2
|
1,0
|
2,2
|
15
|
4A280M6УЗ
|
90,0
|
985
|
0,925
|
0,89
|
1,2
|
1,0
|
2,2
|
16
|
4A315M8УЗ
|
110,0
|
735
|
0,93
|
0,85
|
1,2
|
0,9
|
2,3
|
16
|
4A355S8УЗ
|
132,0
|
740
|
0,935
|
0,85
|
1,2
|
0,9
|
2,2
|
17
|
4A355M8УЗ
|
160
|
740
|
0,935
|
0,85
|
1,2
|
0,9
|
2,2
|
18
|
4A250S10УЗ
|
30,0
|
590
|
0,88
|
0,81
|
1,2
|
1,0
|
1,9
|
19
|
4A280S10УЗ
|
37,0
|
590
|
0,91
|
0,78
|
1,0
|
1,0
|
1,8
|
20
|
4A280M10УЗ
|
45,0
|
590
|
0,915
|
0,78
|
1,0
|
1,0
|
1,8
|
21
|
4A315S10УЗ
|
55,0
|
585
|
0,92
|
0,79
|
1,0
|
0,9
|
1,8
|
22
|
4A315S12УЗ
|
45,0
|
485
|
0,905
|
0,75
|
1,0
|
0,9
|
1,8
|
23
|
4A315M12УЗ
|
55,0
|
490
|
0,91
|
0,75
|
1,0
|
0,9
|
1,8
|
24
|
4A355S12УЗ
|
75,0
|
492
|
0,915
|
0,76
|
1,0
|
0,9
|
1,8
|
25
|
4A355M12УЗ
|
90,0
|
493
|
0,92
|
0,76
|
1,0
|
0,9
|
1,8
|
26
|
4AH160S2УЗ
|
22,0
|
2915
|
0,88
|
0,88
|
1,3
|
1,0
|
2,2
|
26
|
4AH180S2УЗ
|
37,0
|
2950
|
0,91
|
0,91
|
1,2
|
1,0
|
2,2
|
27
|
4AH160S4УЗ
|
18,5
|
1450
|
0,885
|
0,87
|
1,3
|
1,0
|
2,1
|
28
|
4AH225M6УЗ
|
45,0
|
980
|
0,91
|
0,87
|
1,2
|
1,0
|
2,0
|
29
|
4AH250M8УЗ
|
55,0
|
735
|
0,92
|
0,81
|
1,2
|
1,0
|
1,9
|
30
|
4AH315S10УЗ
|
75,0
|
585
|
0,91
|
0,82
|
1,0
|
0,9
|
1,8
|
Izzoh: dvigatel 3 fazali 380V kuchlanishli tarmoqdan ta’minlanadi.
III. Ishni bajarish tartibi:
Dvigatelni salt ishlash va nominal burchak tezliklarini toping.
Nominal sirpanishni aniqlaymiz.
Dvigatelni nominal momentini hisoblaymiz
Kritik momentni aniqlaymiz
Kritik sirpanishni hisoblaymiz.
Dvigatelni mexanik xarakteristikasini qurish uchun Kloss formulasidan foydalaning:
bu formuladagi Sni 0 dan 1 gacha qiymatlari uchun M moment qiymatni hisoblab chiqing va 14.2-jadvalga yozing. 14.2 – jadval:
S
|
0,02
|
0,05
|
0,1
|
0,15
|
0,2
|
0,4
|
0,6
|
0,8
|
1
|
M
|
|
|
|
|
|
|
|
|
|
ω
|
|
|
|
|
|
|
|
|
|
Bunda dvigatelni burchak tezigi quyidagicha aniqlanadi
Jadval bo'yicha s=f(M), ω = f(M) mexanik xarakteritikasi grafigini quring:
IV. Vazifa: Xosil bo'lgan mexanik xarakteristikada dvigatelni turg'un ishlash nuqtalarini aniqlang va buoraliqdan tashqari nuqtalarda dvigatelni ishlash holatlarini izohlab bering.
V. Xulosa: Xulosada asinxron dvigatelini mexanik xarakteristikasini qurish xususiyatlarini yoriting, mexanik xarakteristikalar orqali dvigatelni ish rejimlari to'g'risida ma'lumot bering, dvigatelni mexanik xarakteristikasidagi asosiy nuqtalarini tushuntiring.
Amaliy mashg’ulot № 15
Mavzu 14:O‘zgaruvchan tok motorlarning tabiiy va sun’iy static tavsiflarini hisoblash.
14.2.Asinxron dvigatelni ishga tusirish xarakteristikalarini hisoblash va qurish.
Ishdan maqsad:
Mashgulotdan asosiy maqsad asinxron dvigatellarni ishga tushirish xarakteristikalarini hisoblash va qurishni o’rganish. Dvigatelni ishga tushirish reostatining qarshiliginihisoblashni uddalay olish.
Topshiriq:
Faza rotorli asinxron dvigatelni ishga tushirish rheostat ini qarshiligini hisoblang. Dvigatel 3-4 pog’onali reostat yordamida ishga tushiriladi. Dvigatel parametrlari 14.1-jadvaldan oling (14-amaliy ish).
Ishni bajarisn tartibi:
Dvigatelni tabiiy mexanik xarakteristikasini hisoblang va quring.
Ishga tushirishdagi eng katta momentni hisoblang
M1=0,8Mmax [Hm]
Reostat pog’onalaridan o’tishdagi momentni toping
M2 =1, 3Mн
4.Dvigatel rotorini qarshiligini hisoblang R2н=(Е2 sн)/ I2н
Bunda katalogdan E2н=408 V deb olamiz
5. Reostat pog’onalarini qarshiliklarini toping
R1=(gi/pa) R2н ; R2=(eg/pa) R2н ; R3=(ce/pa) R2н; R4=(ac/pa) R2н.
6. Reostatning umumiy qarshiligini hisoblang Rp=R1+R2+R3+R4
7. Dvigatelni reostat ishga tushirish xarakteristikalarini quring
Vazifa:
Barcha hisoblashlarni bajaring, ularning natijalari bo’yicha ishga tushurish xarakteristikasini quring va grafigini chizing.
Xulosa:
Xulosada dvigatelni ishga tushurish reostatini qarshiliklarini xisoblashning tartibini tushuntiring. Dvigatel ishga tushish paytida pog’onadan-pog’onaga o’tishni izoxlang.
Amaliy mashg’ulot № 16
Mavzu15: O‘zgarruvchan tok motorni tormozlash tavsiflarini hisoblash va qurish
Ishdan maqsad:
Oʻzgaruvchan tok motorlarning tormozlash rejimlardagi tavsiflarini hisoblash va grafigini qurishni o’rganish. Asinxron dvigatelni rekuperativ, teskari ulab va dinamik tormozlash rejimlarini o’rganish, dvigatelni tormozlash uchun ulanadigan qoʻshimcha qarshilik qiymatini hisoblashni oʻrganish.
Topshiriq:
Asinxron dvigatelni tormozlash tavsiflarini hisoblang va xarakteristikalarini quring. Dvigatelning parametrlarini oʻz variantingiz boʻyicha 14.1-jadvaldan oling(14 - amaliy ish), karshilik momentini Mc = 0,73Mн deb oling.
Do'stlaringiz bilan baham: |