Power System Analysis
. McGraw-Hill
Book Co., 1994.
[38] D. F. Binns, M-EngSc., “Calculation of steady-state temperature rise of water-
cooled buried cables using a new iterative method,” Proceedings of the Institution
of Electrical Engineering,1969.
[39] Y. Biçen and F. Aras, “Steady State Effects of Design Properties and
Environmental Conditions on Underground Power Cable Ampacity,” pp. 81–84
2017 10
th
International Conference on Electrical and Electronics Engineering
,
2017.
[40] M. Baù, N. Viafora, C. S. Hansen, L. B. Dall, N. Badulescu, and F. M. F. da Silva,
“Steady State Modelling of Three-core Wire Armoured Submarine Cables,”
Proc.
2016 51st Int. Univ. Power Eng. Conf.
, 2016.
[41] Y. Liang, “Steady-state thermal analysis of power cable systems in ducts using
streamline-upwind/petrov-galerkin finite element method,”
IEEE Trans. Dielectr.
142
Electr. Insul.
, vol. 19, no. 1, pp. 283–290, 2012.
[42] K. Rudion, A. Orths, Z. A. Styczynski, and K. Strunz, “Design of benchmark of
medium voltage distribution network for investigation of DG integration,”
2006
IEEE Power Eng. Soc. Gen. Meet.
, pp. 1–6, 2006.
[43] The Okonite Company, “https://www.okonite.com/.” .
[44] A. Kalbat, “PSCAD simulation of grid-tied photovoltaic systems and Total
Harmonic Distortion analysis,”
2013 3rd Int. Conf. Electr. Power Energy Convers.
Syst. EPECS 2013
, 2013.
[45] A. D. Rajapakse and D. Muthumuni, “Simulation tools for photovoltaic system
grid integration studies,”
2009 IEEE Electr. Power Energy Conf. EPEC 2009
, pp.
1–5, 2009.
[46] A. Kalbat, “PSCAD simulation of grid-tied photovoltaic systems and Total
Harmonic Distortion analysis,”
2013 3rd Int. Conf. Electr. Power Energy Convers.
Syst. EPECS 2013
, pp. 0–5, 2013.
[47] PSCAD Company, “Synchronous Machine Study.”
[48] B. Sun, E. Makram, and X. Xu, “Impacts of Water-Tree Fault on Ferroresonance
in Underground Cables,”
Journal of Power and Energy Eng.
, vol. 5, pp. 75–86,
2017.
[49] G. J. Bertini, “Molecular thermodynamics of water in direct-buried power cables,”
IEEE Electr. Insul. Mag.
, vol. 22, no. 6, pp. 17–23, 2006.
[50] R. C. Dugan, “Examples of ferroresonance in distribution systems,”
2003 IEEE
Power Eng. Soc. Gen. Meet. (IEEE Cat. No.03CH37491)
, vol. 2, pp. 1–3, 2003.
143
[51] Roger C. Dugan, Mark F. McGranaghan, Surya Santoso, H. Wayne Beaty,
“Electrical Power Systems Quality,”
McGraw Hill
, Second Edition, 2003.
[52] D.R.Smith, S.R.Swanson, J.D.Borst, “Transformers, overvoltages with remotely-
switched cable-fed grounded wye-wye transformer,”
IEEE Trans. Power Appar.
Syst.
, vol. 94, no. 5, pp. 1843–1853, 1975.
[53] D. A. N. Jacobson, “Examples of ferroresonance in a high voltage power system,”
2003 IEEE Power Eng. Soc. Gen. Meet. (IEEE Cat. No.03CH37491)
, vol. 2, pp.
1–7, 2003.
[54] N. Thanomsat and B. Plangklang, “Ferroresonance phenomenon in PV system at
LV side of three phase power transformer using of PSCAD simulation,”
13th Int.
Conf. Electr. Eng. Comput. Telecommun. Inf. Technol.
, 2016.
[55] R. A. Walling, “Ferroresonance in low-loss distribution transformers,”
2003 IEEE
Power Eng. Soc. Gen. Meet. (IEEE Cat. No.03CH37491)
, vol. 2, pp. 1220–1222,
2003.
[56] K. W. Burkes, E. B. Makram, and R. Hadidi, “Water Tree Detection in
Underground Cables Using Time Domain Reflectometry,”
IEEE Power Energy
Technol. Syst. J.
, vol. 2, May, pp. 53–62, 2015.
[57] T. Toyoda, S. Mukai, Y. Ohki, Y. Li, and T. Maeno, “Estimation of conductivity
and permittivity of water trees in PE from space charge distribution
measurements,”
IEEE Trans. Dielectr. Electr. Insul.
, vol. 8, no. 1, pp. 111–116,
2001.
[58] P. Sakarung and S. Chatratana, “Application of PSCAD / EMTDC and Chaos
144
Theory to Power System Ferroresonance Analysis,”
Int. Conf. Power Syst.
Transients Montr.
, pp. 19–23, 2005.
[59] J. Densley, “Ageing mechanisms and diagnostics for power cables - an overview,”
IEEE Electr. Insul. Mag.
, vol. 17, no. 1, pp. 14–22, 2001.
[60] F. Aras, V. Alekperov, N. Can, and H. Kirkici, “Aging of 154 kV underground
power cable insulation under combined thermal and electrical stresses,”
IEEE
Electr. Insul. Mag.
, vol. 23, no. 5, pp. 25–33, 2007.
[61] Advanced Cable Bus Company, “http://www.advcablebus.com/.” .
[62] A. Canova, F. Freschi, and M. Tartaglia, “Multiobjective optimization of parallel
cable layout,”
IEEE Trans. Magn.
, vol. 43, no. 10, pp. 3914–3920, 2007.
[63] W. Moutassem, “Configuration Optimization of Underground Cables inside a
Large Magnetic Steel Casing for Best Ampacity,” vol. 25, no. 4, pp. 2037–2045,
2010.
[64] M. M. Haji, D. A. Zarchi, and B. Vahidi, “Optimal configuration of underground
cables to maximise total ampacity considering current harmonics,”
IET Gener.
Transm. Distrib.
, vol. 8, May 2013, pp. 1090–1097, 2014.
[65] B. Sun and E. Makram, “Configuration Optimization of Cables in Ductbank Based
on Their Ampacity,”
Journal of Power and Energy Engineering,
pp. 1–15, 2018.
[66] M. Diaz-Aguiló and F. de León, “Adaptive soil model for real-time thermal rating
of underground power cables,”
IET Sci. Meas. Technol.
, vol. 9, no. 6, pp. 654–660,
2015.
[67] J. Lofberg, “YALMIP : a toolbox for modeling and optimization in MATLAB,”
145
2004 IEEE Int. Conf. Robot. Autom. (IEEE Cat. No.04CH37508)
, pp. 284–289,
2004.
[68] M. Kvasnica and M. Fikar, “Design and implementation of model predictive
control using Multi-Parametric Toolbox and YALMIP,”
Comput. Control Syst.
Des. (CACSD), 2010 IEEE Int. Symp.
, pp. 999–1004, 2010.
Document Outline - Clemson University
- TigerPrints
- Study of Cables in the Distribution System: Parameters Calculation, Fault Analysis, and Configuration Optimization
- tmp.1551908031.pdf.m95CP
Do'stlaringiz bilan baham: |