Страница 1 мировой engineering стандарты общая спецификация


Table 157: Functionally Addressed TesterPresent (no response allowed)



Download 1,29 Mb.
Pdf ko'rish
bet240/435
Sana02.08.2022
Hajmi1,29 Mb.
#846314
1   ...   236   237   238   239   240   241   242   243   ...   435
Bog'liq
WORLDWIDE ENGINEERING STANDARDS General Motors Local Ar

Table 157: Functionally Addressed TesterPresent (no response allowed)
T = Frame Sent By Tester, N = Frame Sent By Node; shaded region indicates PCI
Frame Type CAN Id
#1
#2
#3
#4
#5
#6
#7
#8
T(USDT-SF)
$101
$FE
$01
$3E
---
---
---
---
---
no positive response messages
--``,,``````,``,,``,,,`,`,`,,-`-`,,`,,`,`,,`---


25.06.2020
WORLDWIDE ENGINEERING STANDARDS General Motors Local Area Network Enhanced Diagnostic Test Mode Specification
https://translate.googleusercontent.com/translate_f
157/298
Page 177
GM WORLDWIDE ENGINEERING STANDARDS
GMW3110
© Copyright 2010 General Motors All Rights Reserved
February 2010
Page 177 of 336
8.15.6 Node Interface Function.
8.15.6.1 Node Interface Data Dictionary (Table 158).
Table 158: Node Interface Data Dictionary of TesterPresent Service Pseudo Code
Variable/Meaning
Values
message_address_type
message_data_length
TesterPresent_Timer_State
diagnostic_responses_enabled
TesterPresent_Timer
Reference Common/Global
Pseudo Code Data Dictionary
For Definition Of These
Flags/Variables
8.15.6.2 Node Interface Pseudo Code.
Powerup States:
None
Each time a TesterPresent ($3E) message is received, the following logic is executed:
BEGINFUNCTION Serv_3E_Msg_Recvd()
IF (message_data_length = 1) THEN
TesterPresent_Timer ←
0 /*Reset the tester present timer*/
/* send a pos. resp. if request was physically addressed and diagnostic responses are enabled*/
IF ((message_address_type = PHYSICAL) AND (diagnostic_responses_enabled = YES)) THEN
send ($7E) response message
ENDIF
ELSE
IF (message_address_type = PHYSICAL) THEN
send Negative Response ($7F $3E $12) InvalidFormat
ENDIF
ENDIF
ENDFUNCTION
The following logic is used to implement the TesterPresent_Timer in the node’s main processing loop:
BEGINFUNCTION Serv_3E_Background_Logic()
IF (TesterPresent_Timer_State = ACTIVE) THEN
increment TesterPresent_Timer by the length of the main processing loop
IF (TesterPresent_Timer ≥ P3
C
) THEN
Call Exit_Diagnostic_Services() /* function in service $20 */
ENDIF
ENDIF
ENDFUNCTION

Download 1,29 Mb.

Do'stlaringiz bilan baham:
1   ...   236   237   238   239   240   241   242   243   ...   435




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish