Requirements for Channel Modifications in Unnumbered A Zones


The attached forms are provided to help clarify the data requirements for engineering studies within FEMA Unnumbered (Approximate) A Zones. The forms address engineering requirements necessary to evaluate the impact of proposed developments on flooding. This form is to be used for structural and non-structural activities that modify channels located with Special Flood hazard Areas (SFHA’s) as defined by the Richland County Special Purpose Flood Damage Prevention Resolution (Regulations) as adopted May 28, 1987.
Building standards for protection of structures from flood damage are not addressed by the forms.

Reference material:

The USDA Forest Service publication referenced in the forms and the presentation (General Technical Report RM-245, Stream Channel Reference Sites: An Illustrated Guide to Field Technique) can be downloaded via the Internet at the following address: http://www.stream.fs.fed.us/publications/PDFs/RM245E.PDF

Note: Fill out one form for each flooding source studied
Community Name:


Flooding Source:




Project Name/Identifier:





  1. REACH STUDIED

Describe the limits of the reach being studied or submit a workmap with the study area clearly highlighted. If the reach has been identified by FEMA as a Special Flood Hazard Area, a highlighted FIRM or FHBM should be attached depicting the area of study.


Copy of highlighted FIRM or FHBM attached?  Yes  No
Downstream limit:


Upstream limit:




  1. MODELS REQUIRED - FEMA ZONE A – NO BFE PROVIDED

Purpose of study:


 Determine Base Flood Elevation data for “Subdivisions and Large Developments” (as defined by Regulations Section 5.2-6)

Indicate models submitted below and complete Section 3. Full input and output listings along with files on diskette for items A, B, and C listed below and a summary of the source of input parameters used in the models must be provided. The summary must include a description of any changes made from the Existing or Pre-Project Conditions model to the Revised or Post-Project Conditions model. Delineation of a floodway is recommended, but may not be required.


Models Required:
A. Existing or Pre-Project Conditions Model  Natural        Floodway      

(File name) (File name)

The Existing or Pre-Project Conditions model represents existing conditions at the time the flood study was conducted.

B. Revised or Post-Project Conditions Model  Natural        Floodway      

(File name) (File name)

The Existing or Pre-Project Conditions model is revised to reflect revised or post-project conditions. This model must incorporate any physical changes to the floodplain resulting from the project. When the request for approval is for the proposed project this model must reflect proposed conditions.

C. Other Please attach a sheet describing all other models submitted along with the file names.

 Natural  Floodway

 Perform an impact analysis for alteration of a watercourse

Computer model not required. Complete Section 3.


 Other

Please contact Richland County for information on data requirements for flood studies completed for purposes other than those listed above.



  1. ALTERATION OF WATERCOURSE




    1. Field Determination of Watercourse Geometry:

The horizontal extent of the watercourse must be determined by field observation. It is recommended that bankfull stage, as described in the USDA Forest Service General Technical Report RM-245, Stream Channel Reference Sites: An Illustrated Guide to Field Technique, be used to define the watercourse. Provide a site plan clearly indicating the location of cross-sections where the watercourse geometry has been determined.
Provide a plot of all cross-sections used to determine the bankfull watercourse. Any of the following bankfull indicators that are present, as described in the above referenced report, should be clearly labeled on the cross-section:

1) Top of Pointbars 2) Change in Vegetation 3) Change in Slope

4) Change in Bank Materials 5) Bank Undercuts 6) Stain Lines
The following information should be determined at multiple cross-sections to ensure proper evaluation of the channel bankfull geometry:
1. Bankfull width 2. Bankfull depth/stage 3. Water surface elevation at bankfull stage
Note: Provide a summary table for the information listed above. If bankfull indicators disagree, please attach an explanation for how bankfull determination was made.


    1. Flood Carrying Capacity:




      1. Does the proposed work encroach upon the bankfull watercourse determined above?

 No  Yes


If “No”, the proposed work will not diminish the flood carrying capacity of the watercourse.
If “Yes”, an engineering analysis must be performed that determines the following information for each cross-section:
Existing conditions

Bankfull water surface elevation (as determined above) Bankfull discharge capacity


Proposed conditions

Using the existing conditions bankfull discharge capacity, compute the water surface elevation for the proposed channel configuration.


Note: Provide a summary table and supporting calculations for the information listed above.


      1. Does the proposed channel configuration convey the bankfull discharge without increasing the water surface elevation?

 Yes  No


If “Yes”, the proposed work will not diminish the flood carrying capacity of the watercourse.
If “No”, the proposed work will diminish the flood carrying capacity of the watercourse.


    1. Maintenance of Watercourse:




      1. Does the proposed channel design incorporate concepts/elements intended to prevent increased erosion or sedimentation?

 Yes  No


If “Yes”, please attach plans and an explanation describing how the design elements work to prevent increased erosion or sedimentation.
If “No”, has a maintenance agreement been signed between the permit requestor and an authoritative government entity, so that the flood carrying capacity of the altered or relocated watercourse will not be diminished?

Note: It is recommended that a maintenance agreement between the permit requestor and the appropriate government entity be required that indicates the specific maintenance responsibilities of the requestor.



Page of

Riverine Hydraulic Analysis Form



(Models required - FEMA Zone A - no BFE provided) updated 08/05/2010


Download 86 Kb.

Do'stlaringiz bilan baham:




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish