Page 24 of 41
13
Welding mode (C)
cellulose /MMA/TIG/ mode selector
14
VRD light (C)
When the OCV is less than 18V,the VRD light will be on (green).
15
VRD switch(C)
VRD switch ON: the OCV for MMA, cellulose, gouging function is
less than 18Vdc.
VRD switch off : OCV is 76V for MMA and cellulose ,gouging
process.
16
warning indicator
for welder (B)
When welder is overload ,the thermal protection circuit will be able to
give a signal to stop welder and light up the indicator.
17
Output control (B)
MMA,CELLULOSE ,TIG, :adjust the current output for welder B
18
Current meter
CC mode: Display the presetting current and actual current
19
VRD light (B)
When the OCV is less than 18V,the VRD light will be on (green).
20
VRD switch(B)
VRD switch ON: the OCV for MMA, cellulose, gouging function is
less than 18Vdc.
VRD switch off : OCV is 76V for MMA and cellulose ,gouging
process.
21
warning indicator
for welder (A)
When welder is overload ,the thermal protection circuit will be able to
give a signal to stop welder and light up the indicator.
22
Welding mode (B)
cellulose /MMA/TIG/ mode selector
23
VRD light (A)
When the OCV is less than 18V,the VRD light will be on (green).
24
VRD switch(A)
VRD switch ON: the OCV for MMA, cellulose ,gouging function is
less than 18Vdc .
VRD switch off : OCV is 76V for MMA and cellulose ,gouging
process.
25
Current meter(A)
CC mode: Display the presetting current and actual current
26
Welding mode (A)
cellulose /MMA/TIG/ mode selector
27
Output control (A)
MMA,CELLULOSE ,TIG, :adjust the current output for welder A
28
Arc force(A)
Adjust the arc force for welder A(MMA,CELLULOSE MODE)
28-
1
Hot start (A)
Hot start current to help successfully start the arc
29
Remote control
Remote control for welder A (MMA/TIG /FCAW mode)
30
Water
temperature
alarm indicator
When water temperature is higher than 98
℃
,this indicator (red) will
be lighted on ,
31
oil pressure alarm
indicator
When oil pressure is low than 6.9kpa ,this indicator (red) will be
lighted on ,
32
Battery charging
alarm indicator
When the alternator for battery charging do not output power, this
indicator will be lighted on (red)
33
Fuel level gauge
Display the fuel level of the fuel tank.
34
Engine starter
Start and shut off engine, preheating engine
35
Hour
Record the engine working hours
36
Emergency stop
switch
Do'stlaringiz bilan baham: