Figure 22: ECU P2
CE
* Timing Parameter Definition - Single RC78 and Final SF Response Message 
Figure 23: ECU P2
CE
* Timing Parameter Definition - Single RC78 and Final Multi-Frame
Response Message 
Request
SF-RC78
SF-RSP
ECU Transmit
Tester Transmit
ECU NWL
P2
CE
100
0
Tester NWL
req
con
ind
req
ind
con
req
con
ind
P2
CE
P2CE*
0
Request
SF-RC78
USDT-FF
. . .
USDT-CF
USDT-CF
USDT-FC
USDT-FC
ECU NWL
Tester NWL
Tester Transmit
ECU Transmit
P2
CE
100
0
req
con
ind
req
con
ind
req
ind
con
ind
P2
CE
P2CE*
0
--``,,``````,``,,``,,,`,`,`,,-`-`,,`,,`,`,,`---
CameraLoops.com


GM WORLDWIDE ENGINEERING STANDARDS 
GMW3110 
© Copyright 2010 General Motors All Rights Reserved 
February 2010 
Page 56 of 336 
Figure 24: ECU P2
CE
*Timing Parameter Definition - Multiple RC78 and Final Multi-Frame
Response Message 
Figure 25: ECU P2
CE
*Timing Parameter Definition - Single RC78 and Final UUDT Response Message 
(One or Multiple) 
Note:
The timing that applies to subsequent UUDT messages, optionally transmitted by the ECU following the 
first UUDT message is not shown in the figure above. 
6.2.2.2 Tester Timing Parameter P2
CT
* (Table 30 and Figures 26 thru 28). 
If an ECU requests an enhanced 
response timing by responding with a negative response message with response code $78 then the tester has 
to modify its P2
CT
timer reload value to the value of P2
CT
*. The handling of the enhanced response timing 
using the P2
CT
* timing parameter value is based on the general P2
CT
handling with the exception that the timer 
reload value is modified to be the P2
CT
* timing parameter value. 
Table 30: Tester P2
CT
* Timing Parameter Value 
Parameter 
Description 
Minimum 
(CTmin*) 
 [ms] 
Maximum 
(CTmax*) 
[ms] 
P2
CT

Enhanced response timing value for tester P2
CT
timer. 
5100 
N/A 
Note 1
Note 1:
The value that a tester uses for P2
CTmax
* is left to the discretion of the tester as long as it is greater than P2
CTmin
*. 
The tester shall perform the following handling: 

After correct reception of a negative response message with response code $78 following a request 
message (single frame or multi-frame request message) the P2
CT
parameter timing value shall be set to 
P2
CT
* by the tester and the restart of the P2
CT
timer shall be performed with this new value. 

Each USDT response message (positive and negative response) and the first UUDT response message, 
as defined for the general handling of P2

Download 8,35 Mb.

Do'stlaringiz bilan baham:
1   ...   71   72   73   74   75   76   77   78   ...   406




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish