General Specification Electrical Function gmw3110 General Motors Local Area Network Enhanced Diagnostic Test Mode Specification


Table 134: RequestDownload Response Messages



Download 8,35 Mb.
Pdf ko'rish
bet197/406
Sana03.04.2022
Hajmi8,35 Mb.
#525939
1   ...   193   194   195   196   197   198   199   200   ...   406
Bog'liq
gmw3110

Table 134: RequestDownload Response Messages 
Data Byte Parameter Name 
Cvt 
Hex Value Mnemonic 
#1 
RequestDownload Response Service Id 

74 
SIDPR 
8.12.3.1 Positive Response Message Data Parameter Definition. 
There are no data parameters in a 
response to a request for this service. 
8.12.4 Supported Negative Response Codes (RC_). 
The following negative response codes shall be 
implemented for this service. The circumstances under which each response code would occur are 
documented in Table 135. 
--``,,``````,``,,``,,,`,`,`,,-`-`,,`,,`,`,,`---
CameraLoops.com


GM WORLDWIDE ENGINEERING STANDARDS 
GMW3110 
© Copyright 2010 General Motors All Rights Reserved 
February 2010 
Page 158 of 336 
Table 135: Supported Negative Response Codes 
Hex 
Description 
Cvt 
Mnemonic 
12 
SubFunctionNotSupported-InvalidFormat 

Used if the number of data bytes in the request message is incorrect. 

Used if the requested dataFormatIdentifier value is not supported by the 
node. 

Used if the unCompressedMemorySize is invalid for the dataFormatIdentifier 
requested. 

SFNS-IF 
22 
ConditionsNotCorrectOrRequestSequenceError

This return code shall be sent if the DisableNormalCommunication ($28) 
service is not active when a request is received for this service. 

This return code shall be sent if programming mode has not been activated 
via the ProgrammingMode ($A5) service when a request is received for this 
service. 

This return code shall be sent if the ECU is secure (for ECUs that support 
the SecurityAccess ($27) service) when a request for this service has been 
received. 

This return code shall be sent if an ECU receives a request for this service 
while in the process of receiving a download of a software or calibration 
module. This could occur if there is a data size mismatch between the ECU 
and the tester during the download of a module. 

CNCRSE 
78 

Download 8,35 Mb.

Do'stlaringiz bilan baham:
1   ...   193   194   195   196   197   198   199   200   ...   406




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish