Interpreters Document


Typical Interpreter Line: (all Action and Goto fields are hex numbers)



Download 6,14 Mb.
Pdf ko'rish
bet105/213
Sana03.04.2022
Hajmi6,14 Mb.
#525844
1   ...   101   102   103   104   105   106   107   108   ...   213
Bog'liq
dps Interpreters

Typical Interpreter Line: (all Action and Goto fields are hex numbers) 
Step 
Op-Code 
Action Fields
Goto Fields 
12 
33 
06 00 00 00 
73 13 23 0E 64 99 FF 97 00 00 
CameraLoops.com



1993-2011 General Motors Company, GM Customer Care & Aftersales. All Rights Reserved.
Page
124 
34 Op-Code: SR 34 for Download Request
 
Supported By:
KWP2000 Interpreter 2
 
 
Description: 
The 34 Op-Code will build a standard Service Request 34 to send to an ECU. A request 34 will prepare the 
ECU to receive data from the serial data link. Request 34s are used in conjunction with service request mode 
36s (Op-Codes 90, 91, and 93) to download information to ECU's.
Action Fields: 
AC0: $00 - Not used 
AC1: $00 - Not used
AC2: Data Format Identifier, only used with AC3 equal to $01
AC3: Exceptions: $00 - Standard Service Request 34 message format 
$01 - Include memory address, Data Format ID, and memory size in service request
 
Pseudo Code: 
XX 34 AC0 AC1 AC2 AC3 G0-G1 G2-G3 G4-G5 G6-G7 G8-G9 
Use KWP2000 Normal Response processing
Build Request Download Request as indicated below 
Request 
Byte
Value 
Byte Description 

80 
Format byte for physical addressing 

## 
Global target byte 

## 
Global source byte 

01 
Length of request from byte 5 up to checksum (not included) 

34 
Request download request service ID
If AC3 is $01 
Request 
Byte
Value 
Byte Description 

XX 
Memory address - high byte

XX 
Memory address - middle byte

XX 
Memory address - low byte

AC2 
Data Format Identifier 
10 
XX 
Uncompressed memory size - high byte
11 
XX 
Uncompressed memory size - middle byte
12 
XX 
Uncompressed memory size - low byte
Set the high byte of the memory address to the high byte of the global address set in a F1 Op-Code 
Set the middle byte of the memory address to the middle byte of the global address set in a F1 Op-Code 
Set the low byte of the memory address to the low byte of the global address set in a F1 Op-Code 
Set the Data Format Identifier to the value in AC2 
Set the high byte of the memory size to the high byte of the global size set in a F2 Op-Code 
Set the middle byte of the memory size to the middle byte of the global size set in a F2 Op-Code 
Set the low byte of the memory size to the low byte of the global size set in a F2 Op-Code 
Endif

Download 6,14 Mb.

Do'stlaringiz bilan baham:
1   ...   101   102   103   104   105   106   107   108   ...   213




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish