Basic Programming Principles of PLCs
◾
343
According to the I/O connections of the PLC and the addresses listed, the required Boolean
language program is as follows:
A
I1.0
AN I1.1
S
Q0.0
A
I1.3
R
Q0.0
AN I1.3
A
I1.0
=
Q0.0
A
I1.0
A
I1.1
AN I1.2
S
Q0.2
A
I1.2
R
Q0.2
AN I1.0
R
Q0.0
R
Q0.2
A
I1.3
AN I1.2
O
A
I1.3
AN I1.0
O
A
I1.2
AN I1.1
=
Q0.4
L
MW100
L
‘0.5’
<
=
M3.0
L
MW100
L
‘1.5’
>
=
M4.0
A
I1.3
A
M3.0
=
Q0.2
A
M3.0
=
QX.X
A
M4.0
=
QY.Y
BE
Outputs QX.X and QY.Y are hypothetical that energize indications “Low Cl”
and “High Cl” correspondingly.
Drilling machine automation. In Figure 7.73 a drilling machine is shown, for holes opening on
objects A, which are manually placed by an operator. The machine has a movable cover to protect
the operator from lubricating liquids, insertion of the hands, etc., during the operation of the drill-
ing head. In particular, the machine includes the following equipment:
C
1
= Cylinder that lowers or raises the chuck.
C
2
= Cylinder that lowers or raises the protective cover.
S
0
= Sensor detecting the lower position of the piston C
1
, that is, when the drilling has finished.
S
1
= Sensor detecting the presence of an object in the drilling position.
S
2
= Sensor detecting the lower position of the protective cover.
The stand-by control panel is the two-button control box with which the machine is set to a
stand-by status, which means that it is ready for operation. Also, there is a light indicator express-
ing the “Stand-by ON” status.
The operation control panel is the two-button control box in a double function to start or stop
the drilling procedure.
M = The motor of the drilling head rotation.
The following specifications are valid for the operation of the machine:
1. The initial position of the two pistons is “up”.
2. The machine can operate only if it is in “Stand-by ON” status, i.e., if the “Stand-by ON”
button has been pressed and the readiness indicator lights up.
3. Drilling can only be started if an object has been placed and has been detected by sensor S
1
.
4. If there is an object in the drilling position and the two buttons “start drilling” are pressed
at the same time (requires both hands of the operator for safety reasons), then the protective
344
◾
Introduction to Industrial Automation
cover (activation of the relay C
2
) starts to lower. If the two buttons are released, the cover
returns to its original position.
5. When the protective cover is brought to its final position, it is detected by sensor S
2
and then
the piston C
1
(activation of the relay C
1
) starts to lower, while simultaneously the drilling
head (M) starts its rotation. In this phase, we do not have to press the two “start drilling”
buttons because the protective cover has already been lowered.
6. Piston C
1
and the drilling head press down on the object until drilling is complete. This is
established by the sensor S
0
activation.
Base
Α
S
2
S
1
S
0
C
2
C
1
Protective cover
Left hand
Right hand
Start drilling
Stop drilling
Stand-by
indication
Stand-by ON
Stand-by OFF
PLC
Inputs
Outputs
0 V
+24 V DC
0 V
+24 V DC
I0.0
Q4.1
Μ
I0.3
I0.4
C
1
h
Q4.4
Q5.1 Q
5.4
STOP
START
C
2
STOP
START
STOP
START
S
0
S
1
S
2
I0.1
I0.2
I0.5
I 2.0
I2.1 I2.2
Stand-by
Left hand
Right hand
Do'stlaringiz bilan baham: