Interpreters Document


EE Op-Code: End with ERROR



Download 6,14 Mb.
Pdf ko'rish
bet162/213
Sana03.04.2022
Hajmi6,14 Mb.
#525844
1   ...   158   159   160   161   162   163   164   165   ...   213
Bog'liq
dps Interpreters

EE Op-Code: End with ERROR 
 
Supported By:
UART Interpreter 0 
Class 2 Interpreter 1
 
KWP2000 Interpreter 2 
GMLAN Interpreter 3 
 
Description: 
 
The EE Op-Code is used to signal the tool programming software that an error has occurred. The Interpreter 
will end processing and return to the main software.
The main software will then process any “error codes” that were set from previously executed and failed Op-
Codes. 
Action Fields: 
AC0: 00 - Not Used 
AC1: 00 - Not Used 
AC2: 00 - Not Used 
AC3: 00 - Not Used 
Pseudo Code: 
End reprogramming and return to the main software for “error” processing. 
Typical Interpreter Line: 
Step 
Op-Code 
Action Fields
Goto Fields 
98 
EE 
00 00 00 00 
00 00 00 00 00 00 00 00 00 00 
 
CameraLoops.com



1993-2011 General Motors Company, GM Customer Care & Aftersales. All Rights Reserved.
Page
188 
F1 Op-Code: Set Global Memory Address 
 
Supported By:
UART Interpreter 0 
KWP2000 Interpreter 2
 
GMLAN Interpreter 3
 
 
Description: 
 
The F1 Op-Code is used to set a global memory address for use in applicable Service Requests. The global 
memory address can be used when Op-Codes require address information and the normal address is not 
correct. To use the global address information in an Op-Code, an F1 must be included in the Interpreter 
instructions prior to the Op-Code that is going to use the global address information. The global address 
information can be changed as many times as necessary during a programming event. 
Note: The first (G0) byte of the Goto Field is always set to 0x00 because it is not used (don't care). 
Action Fields: 
AC0: MidHigh byte of address 
AC1: MidLow byte of address
AC2: Low byte of address 
AC3: High byte of address (allows for a 4 byte address value) 
 Pseudo Code: 
XX F1 AC0 AC1 AC2 AC3 G0-G1 G2-G3 G4-G5 G6-G7 G8-G9 
MidHigh byte of global address equals AC0 
MidLow byte of global address equals AC1 
Low byte of global address equals AC2 
High byte of global address equals AC3
Goto step specified in G1 

Download 6,14 Mb.

Do'stlaringiz bilan baham:
1   ...   158   159   160   161   162   163   164   165   ...   213




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish