1993-2011 General Motors Company, GM Customer Care & Aftersales. All Rights Reserved.
Page
199
System Errors and Op-Code Failures
Interpreter system errors will be assigned a global error number when they occur. This error number will be
displayed along with a brief description. Below is a list of the current Interpreter system errors and descriptions
(the descriptions may not match the screen text):
100 - The user requested to quit from the No Communications screen.
101 - Communications failed (maximum retry is three).
102 - The Utility file header contained an Interpreter type that is not supported.
103 - The Goto field of an interpreter step leads to a No Operation Op-Code.
104 - Not used.
105 - Could not find the prolog in the routine section of the Utility file.
106 - Could not find the routine in the routine section of the Utility file.
107 - Invalid storage ID specified in the Interpretive Information.
120 - Encountered a step 00 in the Interpretive Information.
121 - Offset to device routines points beyond the end of the Utility file.
122 - Invalid Section ID for file to download.
123 - Loop step sent to an EE Op-Code on first pass.
160 - Fatal Programming Error - Attempt to program while engine is running or vehicle speed exceeds limit.
161 - Fatal Programming Error - Invalid module ID sent to module.
166 - Fatal Programming Error - Failure to program to zero.
169 - Fatal Programming Error - Failure to Erase.
170 - Fatal Programming Error - Device /Manufacturer code not supported.
171 - Fatal Programming Error - Devices not compatible.
172 - Fatal Programming Error - Security problem.
173 - Fatal Programming Error - Flash reprogram error.
174 - Fatal Programming Error - Checksum fault.
175 - Fatal Programming Error - Processor reset.
213 - Reprogramming Attempt has failed.
281 - Error trying to open a calibration file.
297 - Reprogramming Attempt has failed.
298 - Reprogramming Attempt has failed.
If an Op-Code fails during the programming process the Step and Op-Code that failed will be displayed with a
brief description of what occurred. All error codes are prefaced by the letters SPS before they are displayed to
the user.
For example: SPS05D0 - Invalid response received from the device.
The above error code indicates that a failure occurred during step 05, which was attempting a D0 - Mode 6
Download Calibration/Software File.
The complete list of reprogramming error codes and descriptions will be included in a later version of this
document.