4. Keep the device in enableProgrammingMode for at least 2 minutes by sending TesterPresent (mode $3E)
messages at an interval less than P3
C
ms. Verify that no normal
communication messages are
transmitted.
5. Verify that the device communicates in Programming Mode by periodically sending valid request
messages.
6.
If the device is programmable, verify that the device is capable of being programmed using a released
utility file and the correct interpreter software.
7. Repeat the first 4 steps of this procedure and then send a ReturnToNormalMode ($20) message.
Verify
that the ECU performs a software reset.
8. Repeat the above procedure except end the programming event by allowing a P3
C
(TesterPresent) timeout
to occur (instead of sending a mode $20 request). Verify that the ECU performs a software reset.
Procedure 2:
1. Disable normal communication then send a requestProgrammingMode message ($A5 $01) with extra data
bytes. Verify the negative response ($7F $A5 $12) message.
2. Disable normal communication then send a message with no sub-function parameter byte after the service
Id. Verify the negative response ($7F $A5 $12) message.
3. Disable normal communication then send a message with an invalid sub-function parameter byte after the
service Id. Verify the negative response ($7F $A5 $12) message.
4. Send requestProgrammingMode message ($A5 $01) without disabling normal communication. Verify the
negative response ($7F $A5 $22) message.
5.
If applicable, create conditions under which the node should not allow a programming event to take place.
Then send a requestProgrammingMode message ($A5 $01). Verify the negative response ($7F $A5 $22)
message.
6. Send
a
request
to
enableProgrammingMode
($03)
without
having
previously
sent
a
requestProgrammingMode ($01) request. Verify the negative response ($7F $A5 $22) message.
7. Disable normal communication, send a requestProgrammingMode message ($A5 $01). Verify the positive
response ($E5) message. Send a ReturnToNormalMode ($20) request message
and verify the positive
response. Then send a request to enableProgrammingMode ($03) and verify the negative response ($7F
$A5 $22) message.
8. Disable normal communication, send a requestProgrammingMode message ($A5 $01). Verify the positive
response ($E5) message. Allow a P3
C
timeout to occur
and then send a request to
enableProgrammingMode ($03) and verify the negative response ($7F $A5 $22) message.
9. Repeat steps 1 and 2 of Procedure 1 above. Then send a request for this service with a supported sub-
parameter. Verify the proper negative response (7F $A5 $22) and that there is no impact to the current
programming event. Repeat this procedure for each supported sub-parameter of this service.
10. Repeat steps 1 and 2 of Procedure 1 above. Then send a request for this
service with an unsupported
sub-parameter. Verify the proper negative response (7F $A5 $22) and that there is no impact to the
current programming event.