Electric Motors and Drives This Page Intentionally Left Blank



Download 5,24 Mb.
Pdf ko'rish
bet44/97
Sana13.04.2022
Hajmi5,24 Mb.
#548362
1   ...   40   41   42   43   44   45   46   47   ...   97
Bog'liq
Electric Motors Drives

N
s
Speed
Torque, p.u.
N
Current, p.u.
Current
Torque
1
2
3
6
4
2
Figure 6.12
Typical torque–speed and current–speed curves for a general-purpose
industrial cage motor
Operating Characteristics of Induction Motors
215


trajectory ABC etc. is followed (see Figure 6.13), or continuously so
that maximum torque is obtained throughout. Ultimately the external
resistance is made zero by shorting-out the sliprings, and thereafter the
motor behaves like a low-resistance cage motor, with a high running
e
Y
ciency.
As mentioned earlier, the total energy dissipated in the rotor circuit
during run-up is equal to the
W
nal stored kinetic energy of the motor and
load. In a cage motor this energy ends up in the rotor, and can cause
overheating. In the slipring motor, however, most of the energy goes
into the external resistance. This is a good thing from the motor point of
view, but means that the external resistance has to absorb the thermal
energy without overheating.
Fan-cooled grid resistors are often used, with tappings at various
resistance values. These are progressively shorted-out during run-up,
either by a manual or motor-driven drum-type controller, or with a
series of timed contactors. Alternatively, where stepless variation of
resistance is required, a liquid resistance controller is often employed.
It consists of a tank of electrolyte (typically caustic soda) into which
three electrodes can be raised or lowered. The resistance between
the electrodes depends on how far they are immersed in the liquid.
The electrolyte acts as an excellent short-term reservoir for the heat
released, and by arranging for convection to take place via a cooling
radiator, the equipment can also be used continuously for speed control
(see later).
Attempts have been made to vary the e
V
ective rotor circuit resistance
by means of a
W
xed external resistance and a set of series connected
thyristors, but this approach has not gained wide acceptance.
0
0
Speed
Torque
R = 0
A
B
C
High
Low
rot
or re
sistance
Figure 6.13
Torque–speed curves for a wound-rotor (slipring) motor showing how
the external rotor-circuit resistance
(R)
can be varied in steps to provide an
approximately constant torque during acceleration
216
Electric Motors and Drives


INFLUENCE OF SUPPLY VOLTAGE ON
TORQUE–SPEED CURVE
We established earlier that at any given slip, the air-gap
X
ux density is
proportional to the applied voltage, and the induced current in the rotor
is proportional to the
X
ux density. The torque, which depends on the
product of the
X
ux and the rotor current, therefore depends on the
square of the applied voltage. This means that a comparatively modest
fall in the voltage will result in a much larger reduction in torque
capability, with adverse e
V
ects which may not be apparent to the un-
wary until too late.
To illustrate the problem, consider the torque–speed curves for a cage
motor shown in Figure 6.14. The curves (which have been expanded to
focus attention on the low-slip region) are drawn for full voltage (100%),
and for a modestly reduced voltage of 90%. With full voltage and full-
load torque the motor will run at point X, with a slip of say 5%. Since
this is the normal full-load condition, the rotor and stator currents will
be at their rated values.
Now suppose that the voltage falls to 90%. The load torque is
assumed to be constant so the new operating point will be at Y. Since
the air-gap
X
ux density is now only 0.9 of its rated value, the rotor
current will have to be about 1.1 times rated value to develop the same
torque, so the rotor e.m.f. is required to increase by 10%. But the
X
ux
density has fallen by 10%, so an increase in slip of 20% is called for. The
new slip is therefore 6%.
The drop in speed from 95% of synchronous to 94% may well not be
noticed, and the motor will apparently continue to operate quite hap-
pily. But the rotor current is now 10% above its rated value, so the rotor
heating will be 21% more than is allowable for continuous running.
0
6
0
Slip, %
Torque
5
90%

Download 5,24 Mb.

Do'stlaringiz bilan baham:
1   ...   40   41   42   43   44   45   46   47   ...   97




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish