many cases, metrological self-monitoring opens up even greater possibilities. The organization 
of metrological self-monitoring in sensors is the most relevant. Metrological self-observation 
relies on additional measurement data available or artificially obtained. Metrological self-
control theory is a branch of invariance theory that is used to reduce the influence of certain 
factors on the measurement result [7]. Each of them discusses ways to fill the basic equation of 
changing the measured quantity with one or several additional equations. However, in 
invariance theory, the purpose is to reduce some of the influencing quantities that damage the 
original equation, and metrological self-control is aimed at highlighting the error that results 
from such distortions. In general, it is not possible to fully cover the effects of a hazardous 
exposure, but it is possible to assess the effects of this exposure. Analyses show that the value 
of sensors with metrological self-monitoring in their serial production should not exceed 30-
40% of the value of a similar sensor without this function.
The introduction of a new metrological procedure - metrological self-monitoring - is 
associated with the development of new normative documents in metrological practice. 
Considering the globalization of the market for measuring instruments and metrological 
services, the requirements set out in national standards should take into account foreign 
experience and strive to contribute to the formation of the international regulatory framework. 
Therefore, the development of any relevant standard should be accompanied by a discussion of 
its basic provisions in Uzbekistan and abroad. First of all, manufacturers the measurement tool 
through terminology and users should communicate with metrological self-monitoring and it 
should be standardized. The lack of a common language, especially in the conditions of rapid 
scientific and technological development greatly complicates communication between 
professionals and makes it difficult to find the necessary information, hinders the development 
of science and technology, and provides unfair competition. The second direction of 
standardization is the systematization of metrological self-control methods. Such 
systematization will help to accelerate the development of new measuring instruments with 
metrological self-monitoring, highlight their characteristics and facilitate the exchange of 
experience. 
It is necessary to standardize the requirements for measuring instruments (primarily 
sensors) with metrological self-monitoring. Obviously, the reliability of its results can vary 
depending on the decisions made by the developer. Accordingly, the price of sensors may also 
vary. Metrological self-monitoring features performed on the sensor, which are important for 
the consumer to eliminate unfair competition, should be reflected in the documentation for one.
The third direction is related to the standardization of test methods that prove that the 
characteristics of metrological self-control are consistent with those specified in the documents. 
The standard should ensure that the parameters of the sensors are comparable and that the 
products from different manufacturers are interchangeable. 
Normative documents stipulate that in the systematization of metrological self-
monitoring methods, the high-precision instrument (standard) should have metrological 
reliability than the main measuring transducer, the metrological serviceability of which is 
controlled. 
The simplest example of the organization of the systematization of metrological self-
monitoring methods for measuring temperature is a sensor containing a capsule mounted on a 
metal; its melting point is taken as the value of the standards. The rate of change of temperature 
measured during melting or solidification of a metal decreases significantly, forming a 
temperature-time diagram. Based on the deviation of the measured temperature at the melting 
point of the metal (solidification) from the value of the standards, it is possible to estimate the 
metrological serviceability of the sensor. 
Systematization of metrological self-monitoring methods is similar to the automatic 
calibration procedure. Typically, the measurement can be performed at limited surface of the 
range or at the dynamic characteristics of the sensors. Systematization of metrological self-
monitoring methods is a qualitatively new operation in metrological support. It involves the 



Download 17,18 Mb.

Do'stlaringiz bilan baham:
1   ...   188   189   190   191   192   193   194   195   ...   276




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish