85
slinger / atomizer types. Dehumidification equipment includes the de-
humidifying effect of most cooling coils as well as absorption-type de-
humidifiers.
Thus, the designer has a wide range of equipment to choose from.
Although generalizations are dangerous, some general rules may be
applied, but the designer must also develop, through experience, an
understanding of the best and worst choices. There are some criteria
which are useful:
1. Packaged equipment should be tested, rated, and certified in ac-
cordance with standards of American Society of Heating, Refrigera-
tion, and Air Conditioning Engineers (ASHRAE), Air Conditioning
and Refrigeration Institute (ARI), Association of Home Appliance
Manufacturers (AHAM), Air Movement and Control Association
(AMCA), and / or others as applicable.
2. Minimum unit efficiencies or effectiveness should be in accord-
ance with codes or higher.
3. In general, packaged equipment has a lower first cost and a
shorter life than equipment used in built-up systems. This is not al-
ways true, and comparisons must be made for the specific application.
4. In general, packaged equipment is designed to be as small as
possible for a given capacity. This may create problems of access for
maintenance. Also the supplier should show that capacity ratings
were determined for the package as assembled and not just for the
separate components. See particularly the discussion on the effects of
geometry on fan performance in Chap. 5.
5. In hotel guest rooms, motels and apartments, individual room
units should be used to give occupants maximum control of their en-
vironment. Where many people share the same space, central systems
are preferable, with controls which cannot be reset by occupants.
6. Noise is a factor in almost any HVAC installation, yet noise is
often neglected in equipment selection and installation. Noise ratings
are available for all types of HVAC equipment and should be used in
design and specifications (see Chap. 20).

Download 4,24 Mb.

Do'stlaringiz bilan baham:
1   ...   74   75   76   77   78   79   80   81   ...   581




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish