units may be floor-mounted, exposed, or ceiling-mounted, partially
concealed. The system may use less fan energy than a conventional
system, but piping and control systems become complex. The primary
air supply is constant, and the air supply to a zone may not be shut
off. Noise must be carefully attenuated. These systems found favor in
dormitory and hospital patient wing applications. They were used in
some instances as a perimeter system for office buildings.
11.3
Package Air-Handling Units
A package unit is factory-assembled, ready for installation either in
total or in large segments. This class includes units for rooftop mount-
ing, self-contained units, heat pumps, and split systems—units with
an indoor section and an outdoor section. All these systems may or
may not include factory-installed automatic controls and internal wir-
ing and piping. Field installation may include connections for electri-
cal, fuel, and water service; duct distribution systems; system controls;
and room thermostats.
Package equipment is available in a wide range of capacities; some
rooftop units will provide 100 tons (40,000 to 50,000 ft
3
/ min) or more
of cooling. The advantage of the package unit is the cost and time
saving in field labor. There are some disadvantages. Combinations of
fan and heating / cooling elements may require some compromise for a
specific application—one or more elements may be oversized. Efficien-
cies may be lower than optimum because most package equipment is
made as small as possible for minimum clearances, etc. For the same
reasons, maintenance may be more difficult. Typically, package equip-
ment seems to be installed in less accessible places. Factory-set control
strategies may or may not suit the designer’s needs. Interface with
building automation may be a challenge.
The designer should make sure that all listed capacities are based
on tests of the package as built, rather than the individual compo-
nents. The unit geometry can have an effect, usually detrimental, on
performance (see Sec. 5.2). ASHRAE and the Air Conditioning and
Refrigeration Institute (ARI) publish a number of standards for test-
ing and rating package equipment.

Download 4,24 Mb.

Do'stlaringiz bilan baham:
1   ...   403   404   405   406   407   408   409   410   ...   581




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2025
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish