Chapter hvac engineering Fundamentals: Part 1 Introduction



Download 4,24 Mb.
Pdf ko'rish
bet31/581
Sana01.02.2022
Hajmi4,24 Mb.
#424428
1   ...   27   28   29   30   31   32   33   34   ...   581
Bog'liq
HVAC HANDBOOK

22
Chapter Two
in a research lab seldom knows ‘‘exactly’’ what will be needed, the
HVAC design must be flexible enough to satisfy a wide range of con-
tingencies. This tends to be costly, but is necessary in order to properly
utilize the lab facility. Heat reclaim systems of various kinds are es-
pecially helpful here.
2.8.5
Hospitals
Hospitals are always interesting and challenging for the HVAC de-
signer because of the wide variety of environmental conditions
required in various departments. For example, the operating
suite—with heavily-clothed staff, working under hot lights—requires
a design temperature of about 65 to 70

F, with the relative humidity
held to a range between 50 and 60 percent, and a high percentage of
outside air when the suite is in use. To achieve the clean conditions
needed, the supply air must be filtered through high-efficiency filters,
preferably at or near the discharge into the room, and a high airflow
rate is needed. These requirements all have a rational basis in re-
search; 50 to 55 percent relative humidity (RH) is the value at which
bacteria propagate least readily. Public health authorities prescribe
most of these criteria. Some authorities are allowing reduction of air-
flow and some recirculation when the operating rooms are not in use.
Nurseries do not require high airflow rates but do require about 55
percent RH. Offices, public areas, cafeterias, shops, and other support
areas have similar criteria to other types of buildings. Air is often not
recirculated from patients’ rooms, so individual fan-coil units are com-
mon, combined with a small central ventilation system which provides
makeup air for exhaust. Laboratories have criteria similar to those
described in Sec. 2.8.4.
There are criteria for air-pressure relationshps between occupancies
to keep air moving from high-quality to lower-quality environments.
Air is always exhausted (and scrubbed) from contaminated spaces.

Download 4,24 Mb.

Do'stlaringiz bilan baham:
1   ...   27   28   29   30   31   32   33   34   ...   581




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish