2.3. Listli filtr konussimon dnishesi devorining qalinligini aniqlash (2.3a-rasm).
B e r i l g a n: : ichki bosim P=0,4MPa; filtr balandligi Hs=3500 mm; ichki diametr D=1600 mm; konus cho’qqisining burchagi 2=900; xisoblangan temperatura t=60oC; dnishening materiali po’lat 10; ishchi holat ruxsat etilgan kuchlanish []=127 MPa, gidravlik sinovlar uchun []i=147 MPa; muhit zichligi s=1300 kg/m3; Devorning hisoblangan qalinligiga qo’shimcha c=2,54 mm. Payvand choki mustahkamlik koeffitsiyenti =0,9.
Dnishening hisoblangan va bajaruvchi qalinligi tegishli ravishda quyidagiga tengdir.
2.3 – rasm. Listli vertikal filtr (a) va uning konussimon dnishnning hisoblash sxemasi (b).
1 – qobiq; 2 – qopqoq; 3 – kollektor;
4 – tayanch; 5 – filttrlovchi element.
Sk=sk.p+c+c0=4,84+2,54+0,62 = 8 mm.
(sk-c)/D=(8-2,54)10-3/1,6=3,4410-3; 0,1/cosα=0,1/cos450=0,14 va 3,4410-3<0,14
bo’lganligi uchun, formulani ishlatilish shartlari bajarilyapti.
2-5 jadval
Do'stlaringiz bilan baham: |