Know 580 Well
|
1
|
Naming rule for frequency converter
|
See Section 2.1
|
2
|
Model and mounting dimension of the frequency converter
|
See Section 8.1 and Section 8.2
|
3
|
Mechanical and electrical installation of frequency converter
|
See Section 3.1 and Section 3.2
|
4
|
Reference for model selection of peripheral electrical equipment
|
See Section 8.4
|
5
|
Description of wiring port for frequency converter
|
See Section 3.2
|
6
|
The use of brake resistor and brake unit
|
See Section 8.7
|
7
|
Operation method of operation panel
|
See Section 4.1
|
8
|
Function code organization mode
|
See Section 4.3
|
9
|
How to check the type of frequency converter
|
Check function code F0-00
|
10
|
How to check function code rapidly
|
See Section 4.4
|
11
|
How to check the function code which is different from the default
|
See Section 4.4 and press QUICK key to consult “—C—”
|
12
|
How to save the set value of current function code
|
See Section 4.18
|
13
|
How to restore the previous backup of function code
|
See Section 4.18 and set FP-01=501 before confirmation
|
14
|
How to restore the default of function code
|
See Section 4.18 and set FP-01=1 before confirmation
|
The Operation of 580
|
15
|
Start and stop of the frequency converter
|
Panel control, terminal control, communication control. See Section 4.7.1
|
16
|
What are the start methods
|
Direct start, speed tracking restart, pre-excitation start of asynchronous motor. See Section 4.7.2
|
17
|
What are the stop methods
|
Deceleration stop, free stop
|
18
|
How to make jog by panel buttons
|
See Section 4.7.5.1
|
19
|
How to control the start and stop of terminal
|
See Section 4.7.1.2
|
20
|
How to achieve jog
|
See Section 4.7.5
|
21
|
Frequency setting method of frequency converter
|
See Section 4.8.1 and Section 4.8.2
|
22
|
How to set multi-section frequency setting method
|
See Section 4.8.6
|
23
|
How to set the given operation frequency of upper computer
|
See Section 4.8.1 and Section 4.8.2
|
24
|
How to set the given operation frequency of analog volume
|
See Section 4.8.4
|
25
|
How to set the given operation frequency of the pulse
|
See Section 4.8.5
|
26
|
What are the frequency characteristics in start-up process
|
See Section 4.7.2
|
27
|
How to avoid the frequency resonance point of mechanical equipment
|
See the setting of function codes F8-09, F8-10 and F8-11 and hopping frequency
|
28
|
How to set automatic scheduled stop
|
See Section 4.7.4
|
29
|
How to identify motor parameters
|
See Section 4.9.2
|
30
|
How to set swing frequency mode
|
See Section 4.8.5
|
31
|
How to set the control mode of fixed length
|
See Section 4.8.10
|
32
|
How to use the functions of the counter
|
See Section 4.8.11
|
33
|
Software filter time setting of DI port signal
|
See function code F4-10
|
34
|
Response delay setting of DI signal
|
See Section 4.10 for the setting of function codes F4-35, F4-36 and F4-37
|
35
|
Whether DI signal logic can be changed or not
|
See function codes F4-38 and F4-39
|
36
|
How to set the count of high-speed pulse input
|
See the setting of function code F4-04 and DI5 port
|
37
|
How to set external fault stop
|
Define the function of DI terminal as “11” or “33”
|
38
|
How to set the superposition of main frequency and auxiliary frequency
|
See Section 4.8.2 and the introduction of function code F0-07
|
39
|
How to improve low frequency characteristics of VF control mode
|
See function codes F3-01 and F3-02
|
40
|
Attentions in the long-wire application between the motor and the frequency converter
|
The electric reactor can be set at the output end of frequency converter, as shown in Section 7.3
|
41
|
Analog AI signal calibration
|
See AI calibration of function code AC group
|
42
|
Analog AO signal calibration
|
See AO calibration of function code AC group
|
43
|
The dimension of AI internal read
|
The hundred-mark system % is taken as the unit internally and invisible for the user
|
44
|
How to achieve PID closed-loop control
|
See Section 4.8.4
|
Communication and Expansion Card
|
45
|
The expansion cards for frequency converter
|
See Section 4.16
|
46
|
When is PG card used?
|
See Section 4.14
|
48
|
The communication protocol supported by the frequency converter
|
See Section 4.15
|
49
|
Can multiple function codes or parameters be read through in communication
|
Not allowed, only one function code value or running parameter can be read in one time
|
50
|
Definition of MODBUS communication access address of function code of the frequency converter
|
See Appendix C.1
|
51
|
Running parameters of frequency converter for communication inquiry
|
See Appendix C.2
|
52
|
Start and stop of frequency converter for communication control
|
See Appendix C.2
|
53
|
Operation frequency of the frequency converter for communication control
|
See Appendix C.2
|
54
|
The dimension of operation frequency transmitted to the frequency converter
|
It is the percentage with respect to maximum frequency (F0-10), 0 corresponds to 0% and 10000 corresponds to 100.00%
|