3.1.2 Installation space requirements
The installation space reserved for 580series frequency converter will be different in requirements due to different power levels and the detailed information is as shown in the following figure:
Power level
|
Dimensional requirement
|
0.4-15kW
|
A≥10mm
|
B≥100mm
|
18.5-22kW
|
A≥10mm
|
B≥200mm
|
22-30kW
|
A≥50mm
|
B≥200mm
|
37−315 kW
|
A≥50mm
|
B≥300mm
|
Fig. 3-1 Installation space requirements of 580 frequency converter of different power levels
The heat dissipation of 580 series frequency converter is bottom-up. When many frequency converter are working, the parallel installation will be generally required. On the occasion that upper layer-lower layer parallel installation is required, the heat of frequency converter in lower layer may make the temperature of the equipment in upper layer rise so as to cause failure, therefore, it is necessary to take measures e.g. installation of thermal insulation guide board.
Fig. 3-2 Upper and lower installation drawing of thermal insulation guide board