Page 335
GM WORLDWIDE ENGINEERING STANDARDS
GMW3110


25.06.2020
WORLDWIDE ENGINEERING STANDARDS General Motors Local Area Network Enhanced Diagnostic Test Mode Specification
https://translate.googleusercontent.com/translate_f
297/298
© Copyright 2010 General Motors All Rights Reserved
February 2010
Page 335 of 336
E1.3.8 DTC Failure Sub Type (Symptom) Definition of Bus Signal Failures.
Table E11: DTC Failure Sub Type Definition for Failure Category “7”
Failure
Type
Sub
Type
Bus Signal/Message Failures
Note: 
This category includes faults related to bus hardware and signal integrity. This
category is also used when the physical input for a signal is located in one ECU and
another ECU diagnoses the circuit.
Byte
Nibble 
Sub Type
(hex) (binary) 
Description
Definition
70
0000 reserved
71
0001 invalid serial data received
This sub type is used by the ECU to indicate a signal
was received with the corresponding validity bit equal to
invalid 
or post processing of the signal determines it is
invalid.
72
0010 alive
counter
incorrect/not
updated
This sub type is used by the ECU to indicate a signal
was received without the corresponding rolling count
value being properly updated.
73
0011 parity error
This sub type is used by the ECU to indicate a message
was processed with an incorrect parity calculation.
74
0100 value of signal protection
calculation incorrect
This sub type is used by the ECU to indicate a message
was processed with an incorrect protection (checksum)
calculation.
75
0101 signal above allowable range
This sub type is used for failures where some circuit
quantity, reported via serial data, is above a specified
range.
76
0110 signal below allowable range
This sub type is used for failures where some circuit
quantity, reported via serial data, is below a specified
range.
77
0111 reserved
78
1000 reserved
79
1001 reserved
7A
1010 reserved
7B
1011 reserved
7C
1100 reserved
7D
1101 reserved
7E
1110 reserved
7F
1111 Erratic
This sub type is used for failures where the signal,
reported via serial data, is momentarily implausible or
discontinuous.
--``,,``````,``,,``,,,`,`,`,,-`-`,,`,,`,`,,`---

Download 1,29 Mb.

Do'stlaringiz bilan baham:
1   ...   427   428   429   430   431   432   433   434   435




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish