Страница 1 мировой engineering стандарты общая спецификация


Table 227: Steps of the RequestInfo Process



Download 1,29 Mb.
Pdf ko'rish
bet361/435
Sana02.08.2022
Hajmi1,29 Mb.
#846314
1   ...   357   358   359   360   361   362   363   364   ...   435
Bog'liq
WORLDWIDE ENGINEERING STANDARDS General Motors Local Ar

Table 227: Steps of the RequestInfo Process
Step Action
1
Wake-up link(s) - 
High voltage wake-up for SWCAN 
- gateways may cascade wake-ups (where
applicable) across to the other subnets on the vehicle or the tester may need to use 
level $04 
of
diagnostic service 
InitiateDiagnosticOperation ($10) 
to generate the wake-up (functionally
addressed to gateway ECUs only). 
Note: 
The tester must allow at least 500 ms after issuing a
wake-up before transmitting any diagnostic request message (including tester present) to allow the
ECU to process the wake-up and transition to a communication active state – see paragraph 6.1 for
wake-up requirements.
2
Start sending 
TesterPresent ($3E) 
periodic messages to all nodes - all links as needed (using the
AllNodes CANId and AllNodes extended address).
3
Use service 
ReadDataByIdentifier ($1A) 
service to determine diagnostic addresses and CAN
Identifiers for all ECU(s) (excluding SPS_TYPE_C) on each subnet (setup of base diagnostic
configuration matrix), 
DID $B0.

This determines the relationship of each ECU’s diagnostic address and its physical request and
response CAN Identifiers.

SPS_TYPE_C ECUs would not respond since diagnostic responses have not been enabled yet.

This step and the ReportProgrammedState ($A2) service step which occurs later in the process
allows the utility file to only contain the node diagnostic address. The tester correlates the
diagnostic address to the physical request and response CAN Identifiers.
4
optional
step
Send an 
InitiateDiagnosticOperation ($10) 
request with a sub-parameter value of 
$02
(disableAllDTCs) 
using the AllNodes request CANId and the AllNodes extended address.

This step ensures that nodes that poll the CAN controller do not set DTCs if they do not process


25.06.2020
WORLDWIDE ENGINEERING STANDARDS General Motors Local Area Network Enhanced Diagnostic Test Mode Specification
https://translate.googleusercontent.com/translate_f
241/298
© Copyright 2010 General Motors All Rights Reserved
February 2010
Page 271 of 336
the mode $28 request (in the next step) before they could possibly set signal supervision
failures.
--``,,``````,``,,``,,,`,`,`,,-`-`,,`,,`,`,,`---

Download 1,29 Mb.

Do'stlaringiz bilan baham:
1   ...   357   358   359   360   361   362   363   364   ...   435




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish