8.16.3.1 Positive Response Message Data Parameter Definition (Table 161).
Table 161: Response Message Data Parameter Definition
Definition
programmedState
This data parameter is used to identify for the off board tool which information needs to be programmed into an
node as well as provide an indication of whether or not any memory faults have been detected during the boot
up process. A node may choose which memory faults are appropriate to implement. It may also be possible
that a node may choose to not support the memory faults in this service but provide fault information by setting
a DTC which can be read with the $A9 service.
--``,,``````,``,,``,,,`,`,`,,-`-`,,`,,`,`,,`---
Page 181
GM WORLDWIDE ENGINEERING STANDARDS
GMW3110
8.16.4 Supported Negative Response Codes (RC_). 
The following negative response codes shall be
implemented for this service. The circumstances under which each response code would occur are
documented in Table 162.
Table 162: Supported Negative Response Codes
Hex Description
Cvt Mnemonic
12
SubFunctionNotSupported-InvalidFormat
Used when the request message contains more than the SID byte.
M
SFNS-IF
78
RequestCorrectlyReceived-ResponsePending
This return code is valid if a tester requests this service and the
programmedState calculation has not yet completed.
C
RCR-RP
8.16.5 Message Flow Example ReportProgrammedState.
8.16.5.1 ReportProgrammedState Positive Response Example.
In the following example (Table 163), it is assumed:

There are two SPS programmable nodes on the link.

The $28 service has already been activated.

Node 1 is a programmable node that is fully programmed (SPS_TYPE_A) with a USDT physical response
CANId of $641.

Node 2 is an SPS_TYPE_C ECU that has no operational software or calibration data programmed. The
diagnostic address of this node is $80 (thus the SPS_PrimeRsp CANId shall be $380 and the
SPS_PrimeReq CANId shall be $080).

TesterPresent messages are sent (but not shown in the example).


25.06.2020
WORLDWIDE ENGINEERING STANDARDS General Motors Local Area Network Enhanced Diagnostic Test Mode Specification
https://translate.googleusercontent.com/translate_f
161/298
© Copyright 2010 General Motors All Rights Reserved
February 2010
Page 181 of 336

Download 1,29 Mb.

Do'stlaringiz bilan baham:
1   ...   242   243   244   245   246   247   248   249   ...   435




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish