Страница 1 мировой engineering стандарты общая спецификация


Verification Procedures for Device Control Security Levels (, )



Download 1,29 Mb.
Pdf ko'rish
bet185/435
Sana02.08.2022
Hajmi1,29 Mb.
#846314
1   ...   181   182   183   184   185   186   187   188   ...   435
Bog'liq
WORLDWIDE ENGINEERING STANDARDS General Motors Local Ar

8.8.7.3 Verification Procedures for Device Control Security Levels ($03, $04). 
The procedures below shall
be followed if the ECU supports the Device Control security access levels ($03 and $04). The steps for
Procedure 1 below shall be performed within 10 s of the ECU being powered up (executing operational
software). For procedures 2 through 6 below, the verification procedures shall be performed after the ECU has
been powered up (executing operational software) for at least 10 s.
--``,,``````,``,,``,,,`,`,`,,-`-`,,`,,`,`,,`---
Page 135
GM WORLDWIDE ENGINEERING STANDARDS
GMW3110
Procedure 1:
1. Send a valid security access request message $03 within 10 s of power-up to an ECU when the
vulnerability_flag !=$FF (if supported) and the MEC = $00. Verify $7F $27 $37 response.
2. Repeat step 1 of this procedure periodically (approximately every 500 ms) and verify that the $7F $27 $37
response is sent each time until the ECU has been powered for 10 s.
3. Send a valid security access request message $03 within 10 s of power-up to an ECU when the MEC >
$00 and vulnerability flag not equal to $FF (if supported). Verify the proper positive response message $67
$03 $00 $00.


25.06.2020
WORLDWIDE ENGINEERING STANDARDS General Motors Local Area Network Enhanced Diagnostic Test Mode Specification
https://translate.googleusercontent.com/translate_f
120/298
© Copyright 2010 General Motors All Rights Reserved
February 2010
Page 135 of 336
4. Send a valid security access request message $03 within 10 s of power-up to an ECU when the MEC
equals $00 and vulnerability flag is set to $FF (if supported). Verify the proper positive response message
$67 $03 $00 $00.
Procedure 2: 
This procedure is to be performed twice, once while the ECU has the service device control
restrictions active and once while the ECU has the assembly plant device control restrictions active.
1. Send a security access request message $03 with an incorrect number of data bytes and verify $7F $27
$12 response.
2. Send a security access request message $04 without sending a security access request message $03 and
verify $7F $27 $22.
3. Send a valid security access request message $03 and verify the security access positive response
message $03. Then send a request message $04 with an incorrect number of data bytes and verify the
$7F $27 $12 response.

Download 1,29 Mb.

Do'stlaringiz bilan baham:
1   ...   181   182   183   184   185   186   187   188   ...   435




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish