The height of the intake and discharge water levels affects the flow through the 
pump. This section is used to calculate the static head.
Each combination of input and output levels needs to be entered as a separate 
operating condition. The spreadsheet allows you to enter six conditions. Selecting 
six points will normally be a simplification of the real system. It is useful to include 
the conditions that cause the maximum and minimum differences in levels in these 
six conditions. See the diagrams in sections 8.6.4 and 8.6.5 and on the diagrams 
page of the spreadsheet for more details about the levels. 
5 How does the site operate?
Hours run per year
Level Description
Units
Intake level
m
Discharge level
m
% Time
%
Total
0 %
The percentages need to add up to 100%
Water Levels
0%
0%
0%
0%
0%
0%
0%
20
%
40
%
60
%
80
%
10
0%
Pump Efficiency at Operating Points
Hours run per year 
The typical number of hours that this pump runs for in a year. The actual hours may 
vary from year to year. 
Level description 
Allows you to enter a description. e.g. “Winter Flood” or “Normal Water Levels” 
Intake Level 
This is the water level adjacent to the pump intake. This should be the level on the 
pump side of any weed or trash screens. You will need to use your judgement to 
account for items such as changing intake levels as the level in the sump is pumped 
down. 
See the diagrams in sections 8.6.4 and 8.6.5 and on the diagrams page of the 
spreadsheet for more details about the levels. 
Delivery Level 
The water level at the discharge of the system. For submerged discharge this will be 
the water level on the discharge side. For open discharge the level of the top of the 
pipe should be used. (Soffit level) 
See the diagrams in sections 8.6.4 and 8.6.5 and on the diagrams page of the 
spreadsheet for more details about the levels. 
Percentage Time 
An estimate of the number of pump run hours that are completed at this combination 
of inlet and delivery levels entered from 0 to 100. The percentages for all of the 
water levels used needs to add up to 100. 
Pump Efficiency at Operating Points 
This chart shows the calculated pump efficiency of operating the pumping station 
with these water levels. This chart is also shown on the pump curves sheet and is 
repeated here for quick reference. 


40 
8.3.6 

Download 3,13 Mb.

Do'stlaringiz bilan baham:
1   ...   19   20   21   22   23   24   25   26   ...   37




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish