Service Manual Front Cover. Pdf



Download 493,63 Kb.
Pdf ko'rish
bet2/2
Sana10.01.2023
Hajmi493,63 Kb.
#898594
1   2
Bog'liq
0bd3e42ebf458643772263d0c6cc4003942e4ce37944761509e008243990c072

Document Outline

  • P34x/EN T/E33
    • Contents
    • Issue control
    • Handling of electronic equipment
    • Safety section
    • Introduction (P34x_EN_IT_F33)
      • Table of contents
      • Table of figures
      • INTRODUCTION TO MiCOM
      • INTRODUCTION TO MiCOM GUIDES
      • USER INTERFACES AND MENU STRUCTURE
        • Introduction to the relay
          • Front panel
          • Relay rear panel
        • Introduction to the user interfaces and settings options
        • Menu structure
          • Protection settings
          • Disturbance recorder settings
          • Control and support settings
        • Password protection
        • Relay configuration
        • Front panel user interface (keypad and LCD)
          • Default display and menu time-out
          • Menu navigation and setting browsing
          • Password entry
          • Reading and clearing of alarm messages and fault records
          • Setting changes
        • Front communication port user interface
        • Rear communication port user interface
          • Courier communication
          • MODBUS communication
          • IEC 60870-5 CS 103 communication
          • DNP 3.0 Communication
        • Second rear communication port
    • Application Notes (P34x_EN_AP_F33)
      • Table of contents
      • Table of figures
      • INTRODUCTION
        • Protection of generators
        • MiCOM Generator protection relays
          • Protection features
          • Non-protection features
      • APPLICATION OF INDIVIDUAL PROTECTION FUNCTIONS
        • Configuration column
        • CT and VT ratios
        • Generator differential protection
          • Biased differential protection
          • Setting guidelines for biased differential protection
          • High impedance differential protection
          • Setting guidelines for high impedance differential protection
          • Interturn (split phase) protection
            • Differential interturn protection
              • Setting guidelines for differential interturn protection
            • Application of biased differential protection for interturn protection
            • Application of overcurrent protection for interturn protection
            • Interturn protection by zero sequence voltage measurement
        • Phase fault overcurrent protection
          • RI curve
          • Application of timer hold facility
          • Setting guidelines for overcurrent protection
        • System back-up protection
          • Voltage dependant overcurrent protection
            • Voltage controlled overcurrent protection
            • Voltage restrained overcurrent protection
            • Setting guidelines for voltage controlled overcurrent function
          • Under impedance protection
            • Setting guidelines for under impedance function
        • Undervoltage protection function (27)
          • Setting guidelines for undervoltage protection
        • Overvoltage protection
          • Setting guidelines for overvoltage protection
        • Underfrequency protection
          • Setting guidelines for underfrequency protection
        • Overfrequency protection function
          • Setting guidelines for overfrequency protection
        • Field failure protection function (40)
          • Setting guidelines for field failure protection
            • Impedance element 1
            • Impedance element 2
            • Power factor element
        • Negative phase sequence thermal protection
          • Setting guidelines for negative phase sequence thermal protection
        • Reverse power/over power/low forward power
          • Sensitive power protection function
          • Low forward power protection function
          • Reverse power protection function
            • Reverse power setting guideline
          • Over power protection
            • Over power setting guideline
        • Stator earth fault protection function
          • IDG curve
          • Setting guidelines for stator earth fault protection
        • Residual overvoltage/neutral voltage displacement protection function
          • Setting guidelines for residual overvoltage/neutral voltage displacement protection
        • Sensitive earth fault protection function
          • Setting guidelines for sensitive earth fault protection
        • Restricted earth fault protection
          • Low impedance biased differential REF protection
            • Setting guidelines for low impedance biased REF protection
          • High impedance restricted earth fault protection
            • Setting guidelines for high impedance REF protection
        • 100% stator earth fault protection
          • Setting guidelines for 100% stator earth fault protection
        • Overfluxing protection
          • Setting guidelines for overfluxing protection
        • Dead machine/unintentional energisation at standstill protection
          • Setting guidelines for dead machine protection
        • Resistive temperature device (RTD) thermal protection
          • Setting guidelines for RTD thermal protection
        • P342 Pole slipping protection
          • Reverse power protection
          • System back-up protection function
          • Field failure protection function
        • P343 Pole slipping protection
          • Introduction
          • Loss of synchronism characteristics
          • Generator pole-slipping characteristics
            • What happens if EG / ES has different values less than one (1)?
            • What happens if different system impedances are applied?
            • How to determine the generator reactance during a pole slipping condition?
            • How to determine the slip rate of pole-slipping?
          • General requirements for pole slipping protection
          • Lenticular scheme
            • Characteristic
            • Generating and motoring modes
          • Pole slipping protection operation
            • State machine
            • Protection functions and logic structure
            • Motoring mode
            • Generating and motoring mode
          • Setting guidelines for pole slipping protection
          • Example calculation
        • Thermal overload protection
          • Introduction
          • Thermal replica
          • Setting guidelines
        • Circuit breaker failure protection
          • Breaker failure protection configurations
          • Reset mechanisms for breaker fail timers
          • Typical settings
            • Breaker fail timer settings
          • Breaker fail undercurrent settings
        • Breaker flashover protection
        • Blocked overcurrent protection
        • Current loop inputs and outputs
          • Current loop inputs
          • Setting guidelines for current loop inputs
          • Current loop outputs
          • Setting guidelines for current loop outputs
      • APPLICATION OF NON-PROTECTION FUNCTIONS
        • VT supervision
          • Loss of all three phase voltages under load conditions
          • Absence of three phase voltages upon line energisation
            • Inputs
            • Outputs
          • Menu settings
        • CT supervision
          • The CT supervision feature
          • Setting the CT supervision element
        • Circuit breaker state monitoring
        • Pole dead logic
        • Circuit breaker condition monitoring
          • Circuit breaker condition monitoring features
          • Setting guidelines
            • Setting the sum of the broken currents thresholds
            • Setting the number of operations thresholds
            • Setting the operating time thresholds
            • Setting the excessive fault frequency thresholds
          • Circuit breaker state monitoring features
        • Trip circuit supervision (TCS)
          • TCS scheme 1
            • Scheme description
          • Scheme 1 PSL
          • TCS scheme 2
            • Scheme description
          • Scheme 2 PSL
          • TCS scheme 3
            • Scheme description
          • Scheme 3 PSL
        • Event & fault records
          • Change of state of opto-isolated inputs
          • Change of state of one or more output relay contacts
          • Relay alarm conditions
          • Protection element starts and trips
          • General events
          • Fault records
          • Maintenance reports
          • Setting changes
          • Resetting of event/fault records
          • Viewing event records via MiCOM S1 support software
          • Event filtering
        • Disturbance recorder
        • Measurements
          • Measured voltages and currents
          • Sequence voltages and currents
          • Power and energy quantities
          • Rms. voltages and currents
          • Demand values
            • Fixed demand values
            • Rolling demand values
            • Peak demand values
          • Settings
            • Default display
            • Local values
            • Remote values
            • Measurement REF
            • Measurement mode
            • Fixed demand period
            • Rolling sub-period and number of sub-periods
        • Changing setting groups
        • Control inputs
        • VT connections
          • Open delta (vee connected) VT's
          • VT single point earthing
        • PSL DATA column
        • Auto reset of trip LED indication
      • CURRENT TRANSFORMER REQUIREMENTS
        • Generator differential function
          • Biased differential protection
          • High impedance differential protection
        • Voltage dependent overcurrent, field failure and negative phase sequence protection functions
        • Sensitive directional earth fault protection function residual current input
          • Line current transformers
          • Core balanced current transformers
        • Stator earth fault protection function
          • Non-directional definite time/IDMT earth fault protection
          • Non-directional instantaneous earth fault protection
        • Restricted earth fault protection
          • Low impedance
          • High impedance
        • Reverse and low forward power protection functions
          • Protection class current transformers
          • Metering class current transformers
        • Converting an IEC185 current transformer standard protection classification to a kneepoint voltage
        • Converting IEC185 current transformer standard protection classification to an ANSI/IEEE standard voltage rating
      • COMMISSIONING TEST MENU
        • Opto I/P status
        • Relay O/P status
        • Test port status
        • LED status
        • Monitor bits 1 to 8
        • Test mode
        • Test pattern
        • Contact test
        • Test LEDs
        • Using a monitor/download port test box
    • Relay Description (P34x_EN_HW_F33)
      • Table of contents
      • Table of figures
      • RELAY SYSTEM OVERVIEW
        • Hardware overview
          • Processor board
          • Input module
          • Power supply module
          • RTD board
          • IRIG-B board
          • Second rear comms board
        • Software overview
          • Real-time operating system
          • System services software
          • Platform software
          • Protection and control software
          • Disturbance recorder
      • HARDWARE MODULES
        • Processor board
        • Internal communication buses
        • Input module
          • Transformer board
          • Input board
          • Universal opto isolated logic inputs
        • Power supply module (including ouput relays)
          • Power supply board (including EIA(RS)485 communication interface)
          • Output relay board
        • RTD board
        • IRIG-B board
        • Mechanical layout
        • Second rear communications board
        • Current loop input output board (CLIO)
      • RELAY SOFTWARE
        • Real-time operating system
        • System services software
        • Platform software
          • Record logging
          • Settings database
          • Database interface
        • Protection & control software
          • Overview - protection & control scheduling
          • Signal processing
          • Programmable scheme logic
            • PSL data
          • Event, fault & maintenance recording
          • Disturbance recorder
      • SELF TESTING & DIAGNOSTICS
        • Start-up self-testing
          • System boot
          • Initialisation software
          • Platform software initialisation & monitoring
        • Continuous self-testing
    • Technical Data (P34x_EN_TD_F33)
      • Table of contents
      • Table of figures
      • RATINGS
        • Currents
        • Voltages
        • Auxiliary voltage
        • Frequency
        • 'Universal' logic inputs (P340 range)
        • Output relay contacts
        • Field voltage
        • Loop through connections
        • Wiring requirements
      • BURDENS
        • Current circuit
        • Voltage circuit
        • Auxiliary supply
        • Optically-isolated inputs
      • ACCURACY
        • Reference conditions
        • Influencing quantities
      • HIGH VOLTAGE WITHSTAND
        • Dielectric withstand
        • Impulse
        • Insulation resistance
        • ANSI dielectric withstand
      • ELECTRICAL ENVIRONMENT
        • Performance criteria
          • Class A
          • Class B
          • Class C
        • Auxiliary supply tests, dc interruption, etc.
          • DC voltage interruptions
          • DC voltage fluctuations
        • AC voltage dips and short interruptions
          • AC voltage short interruptions
          • AC voltage dips
        • High frequency disturbance
        • Fast transients
        • Conducted/radiated emissions
          • Conducted emissions
          • Radiated emissions
        • Conducted/radiated immunity
          • Conducted immunity
          • Radiated immunity
          • Radiated immunity from digital radio telephones
        • Electrostatic discharge
        • Surge immunity
        • Power frequency magnetic field
        • Power frequency interference
        • Surge withstand capability (SWC)
        • Radiated immunity
      • ATMOSPHERIC ENVIRONMENT
        • Temperature
        • Humidity
        • Enclosure protection
      • MECHANICAL ENVIRONMENT
        • Performance criteria
          • Severity classes
          • Vibration (sinusoidal)
          • Shock and bump
          • Seismic
      • EC EMC COMPLIANCE
      • EC LVD COMPLIANCE
      • PROTECTION FUNCTIONS
        • Generator differential protection (87G) {P343}
          • Setting ranges
          • Accuracy
        • 2-Stage non-directional overcurrent (50/51)
          • Reset characteristics
          • RI curve
          • Accuracy
        • Restricted earth fault (low impedance)
          • Accuracy
        • 2-Stage non-directional earth fault (50N/51N)
          • Setting ranges
          • Time delay settings
            • Accuracy
          • IDG curve
        • Neutral displacement/residual overvoltage (59N)
          • Setting ranges
          • Time delay settings
          • Accuracy
        • Sensitive directional earth fault (67N)
          • SEF accuracy
          • Wattmetric SEF accuracy
          • Polarising quantities accuracy
        • 100% Stator earth fault {P343}
          • Accuracy
        • Voltage dependent overcurrent (51V)
          • Accuracy
        • Transient overreach and overshoot
          • Accuracy
        • Under impedance (21)
          • Accuracy
        • Under voltage (27)
          • Level settings
          • Under voltage protection time delay characteristics
          • Accuracy
        • Over voltage (59)
          • Level settings
          • Over voltage protection time delay characteristics
          • Accuracy
        • Under frequency (81U)
          • Accuracy
        • Over frequency (81O)
          • Accuracy
        • Reverse power/low forward power/over power (32R/32L/32O)
          • Accuracy
        • Sensitive reverse power/low forward power/over power (32R/32L/32O)
          • Accuracy
        • Field failure (40)
          • Accuracy
        • Negative phase sequence thermal (46)
          • Accuracy
        • Volts/Hz (24)
          • Accuracy
        • Unintentional energisation at standstill (dead machine) {P343}
          • Accuracy
        • Resistive temperature detectors
          • Accuracy
        • Pole slipping (78) {P343}
          • Accuracy
          • Hysteresis
        • Thermal overload (49) {P343}
          • Accuracy
      • SUPERVISORY FUNCTIONS
        • Voltage transformer supervision
          • Accuracy
        • Current transformer supervision
          • Accuracy
      • PROGRAMMABLE SCHEME LOGIC
        • Level settings
        • Accuracy
      • MEASUREMENTS AND RECORDING FACILITIES
        • Measurements
        • IRIG-B and real time clock
          • Features
          • Performance
        • Current loop input and outputs (CLIO)
          • Accuracy
          • Other specifications
      • DISTURBANCE RECORDS
        • Level settings
        • Accuracy
      • PLANT SUPERVISION
        • CB state monitoring control and condition monitoring
          • CB monitor settings
          • CB control settings
          • Accuracy
        • CB fail and backtrip breaker fail
          • Timer settings
          • Timer accuracy
          • Undercurrent settings
          • Undercurrent accuracy
      • INPUT AND OUTPUT SETTING RANGES
        • CT and VT ratio settings
      • BATTERY LIFE
      • FREQUENCY RESPONSE
      • LOCAL AND REMOTE COMMUNICATIONS
        • Front port
        • Rear port
          • Performance
        • Second rear communications port
    • SCADA Communications (P34x_EN_CT_F33)
      • Table of contents
      • INTRODUCTION
      • COURIER INTERFACE
        • Courier protocol
        • Front courier port
        • Supported command set
        • Relay courier database
        • Setting changes
          • Method 1
          • Method 2
          • Relay settings
          • Setting transfer mode
        • Event extraction
          • Automatic event extraction
          • Event types
          • Event format
          • Manual event record extraction
        • Disturbance record extraction
        • Programmable scheme logic settings
      • MODBUS INTERFACE
        • Communication link
        • MODBUS functions
        • Response codes
        • Register mapping
        • Event extraction
          • Manual selection
          • Automatic extraction
          • Record data
        • Disturbance record extraction
          • Manual selection
          • Automatic extraction
          • Record data
        • Setting changes
          • Password protection
          • Control and support settings
          • Protection and disturbance recorder settings
        • Date and time format (data type G12)
        • Power & energy measurement data formats (G29 & G125)
          • Data type G29
          • Data type G125
      • IEC60870-5-103 INTERFACE
        • Physical connection and link layer
        • Initialisation
        • Time synchronisation
        • Spontaneous events
        • General interrogation
        • Cyclic measurements
        • Commands
        • Test mode
        • Disturbance records
        • Blocking of monitor direction
      • DNP3 INTERFACE
        • DNP3 protocol
        • DNP3 menu setting
        • Object 1 binary inputs
        • Object 10 binary outputs
        • Object 20 binary counters
        • Object 30 analogue input
        • DNP3 configuration using MiCOM S1
          • Object 1
          • Object 20
          • Object 30
      • SECOND REAR COMMUNICATIONS PORT (COURIER)
        • Courier protocol
        • Event extraction
        • Disturbance record extraction
        • Connection to the second rear port
      • SK5 PORT CONNECTION
    • Relay Menu Database (P34x_EN_GC_F33)
    • External Connection Diagrams (P34x_EN_CO_F33)
    • Hardware/Software Version History and Compatibility (P34x_EN_VC_E33)

Download 493,63 Kb.

Do'stlaringiz bilan baham:
1   2




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish