The Complex Exponential Forcing Function
7.9
(
) [
]
(
)[
] [
]
j
Ae
j
Ae
Ae
e
j t
j t
j t
j t
w
w
w
w
w
w
2
3
+
+
=
Since this has to be true for all
t, we cancel out
e
j
w
t
and get
[(
)
(
)
]
.
j
j
A
w
w
2
3
1
1
+
+
=
The solution
is completed by solving for
A.
i
j
e
j
e
e
j t
j
j t
2
2
2 2
2
1
1
3
1
1
9
=
−
+
=
−
+
=
(
)
(
)
,
ta
w
w
w
w
f
w
w
f
where
nn
−
−
1
2
3
1
w
w
We note that each differentiation in time has got replaced by a multiplication by j
w
in the equation
determining the complex amplitude in the assumed particular solution. Once we appreciate that
point, we can straightaway obtain the equation governing the complex amplitude
A of the steady-state
response to a complex exponential input by replacing every differentiation in the differential equation
by
a multiplication by j
w
and solve for
A easily.
Let us generalise this. We consider a linear circuit with one sinusoidal source at angular frequency
of
w
driving it. If there are more sources, we employ superposition principle and solve many single-
source circuits. Hence, the basic problem is to solve the circuit for a single source. The most general
differential equation governing a chosen response variable
for a linear circuit is
d y
dt
a
d
y
dt
a
dy
dt
a y
b
d x
dt
b
d
x
dt
n
n
n
n
n
m
m
m
m
+
+ +
+
=
+
−
−
−
−
−
−
1
1
1
1
0
1
1
1
m
m
++ +
+
b
dx
dt
b x
1
0
(7.2-4)
where
y is the chosen response variable,
x is the input function and a’s and
b’s are real positive
constants decided by circuit parameters. The order of differential equation,
n, is
equal to the number
of independent energy storage elements in the circuit.
If
x
=
e
j
w
t
, then
y
=
A e
j
w
t
, where
A is a complex amplitude
decided by the equation
A j
a
j
a j
a
b
j
b
j
b
n
n
n
m
m
m
[(
)
(
)
(
)
]
(
)
(
)
(
w
w
w
w
w
+
+ +
+
=
+
+ +
−
−
−
−
1
1
1
0
1
1
1
m
jj
b
w
)
.
+
0
Therefore, the complex amplitude of steady-state response to a unit amplitude complex exponential
input comes out as a ratio of rational polynomials in the variable
j
w
. The desired steady-state response
is obtained as
y
b j
j
a j
e
k
k
k
m
n
i
i
i
n
j t
=
+
=
=
−
∑
∑
(
)
(
)
(
)
.
w
w
w
w
0
0
1
Hence, solving for steady-state response to complex exponential function
is much simpler and
more elegant than solving for steady-state response to cosine or sine input functions. Therefore,
trying to obtain sinusoidal steady-state response indirectly from steady-state
response to complex
exponential input function is worthwhile.
The method based on Eqn. 7.2-2 and superposition principle – we called it the first method – is the
Electronics and Communication Engineer’s favourite. Electrical Power Engineers usually prefer the
second method that is based on Eqn. 7.2-3 and superposition principle. Both lead to the same result
of course. But, the analysis of sinusoidal steady-state response from the so-called
phasor concept
evolves from the second method. Hence, we take up the second method for detailed discussion.
In this method, we obtain sinusoidal steady-state response for cos
w
t by obtaining the
real part of
7.10
The Sinusoidal Steady-State Response
steady-state response to
e
j
w
t
input. The sinusoidal steady-state response for sin
w
t input is similarly
the
imaginary part of steady-state response to
e
j
w
t
input. A separate determination of response for
cosine and sine input is unnecessary. sin
w
t is 90
°
phase delayed version
of cos
w
t and therefore it must
be possible to obtain the steady-state response for sin
w
t input by delaying the steady-state response
for cos
w
t input by 90
°
. We will verify this in later sections.
Do'stlaringiz bilan baham: