Interpreters Document


Appendix F - Related Documents



Download 6,14 Mb.
Pdf ko'rish
bet210/213
Sana03.04.2022
Hajmi6,14 Mb.
#525844
1   ...   205   206   207   208   209   210   211   212   213
Bog'liq
dps Interpreters

Appendix F - Related Documents 

CD-1039 
 

CD-1036

UART Programmers Quick Reference Guide 
– XDE 5024 
 

Keyword Protocol 2000 Part 1: Physical Layer

Keyword Protocol 2000 Part 2: Communication, and Error Handling 

Keyword Protocol 2000 Part 3: Implementation 

GME12000 Diagnostic Protocol KWP2000 Functional Description

XDE-1039 Generic UART Flash Programming Communications Protocol and Software Requirements 

XDE-1045 Generic Class 2 Flash Programming Communications Protocol and Software Requirements

XDE-3001B General Motors Class 2 Message Strategy and Application 

SAE J-2190 Enhanced E/E Diagnostic Test Modes

Corporate ALDL Data Communications Specification
 

GMW 3110 GMLAN Enhanced Diagnostic Test Mode Specification 
 
CameraLoops.com



1993-2011 General Motors Company, GM Customer Care & Aftersales. All Rights Reserved.
Page
251 
Appendix G 
– $54 Op-Code Additional Information 
Helpful hints on using Op-Code $54:
(The best way to explain it is by example 
– see below.) 
Op-Code $54: Description / Action Fields / Pseudo Code 
See Op-Code $54 information 
above (“Communications Independent Programming Op-Codes”). 
General Information (typical scenario): 
 
1) The application has 20 
“internal” storage buffers to temporarily hold data (mostly vehicle data). These storage 
buffers can be thought of as storage buffer #1 through #20; however, most Op-Codes (and internal code) refer 
to these buffers as #0x00 through #0x13. 
In addition, the 256 bytes of data within a single storage buffer is referenced by starting at position #00 and 
going up to position #255 ($FF 
hexadecimal). This referencing is done by “most” Op-Codes (including this 
Op-Code) and also within internal code.
Also, bit positions are referenced starting at position 0 through position 7 (and NOT 1-8). 
2) 
Data can be placed into these storage buffers via a “Read Data” type of OpCode ($1A for GMLAN).
3) OpCode $54 can then be used to change the data within one of these 
“internal” storage buffers. More than 
one OpCode $54 line may need to be in the utility file if multiple data bytes/bits need to change. 
4) 
And finally, this newly “manipulated” data can be written back into the controller, typically with a “write data” 
type of OpCode ($3B for GMLAN). 

Download 6,14 Mb.

Do'stlaringiz bilan baham:
1   ...   205   206   207   208   209   210   211   212   213




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish