Selects the type of meter input connected to the instrument.
Select one of the following options:
RESISTOR PULL UP* (for open collector type inputs)
RESISTOR PULL DOWN (for Namur type inputs) Flowmeter Filter Meter 1:
Selects whether filtering is applied to the meter input connection.
DEBOUNCE INACTIVE*
DEBOUNCE ACTIVE 7.2.4 Overrun Quantity Meter 1 Overrun Quantity:
The overrun quantity is the amount of product that flows during the
time it takes the flow control valve to close.
36
The instrument signals the flow control valve to close when the
quantity delivered equals the preset quantity less the overrun
quantity.
Enter a value in the following range:
0 to 250 (0*)