Pribor Disk-250 shiroko primenyayutsya izmereniya, registratsii, signalizatsii temperaty, davleniya, rashoda, urovnya va boshqa parametrovlar uchun tizimlarni tartibga solish va texnologik jarayonlarni boshqarish va energetika, metallurgiya, ximicheskoy, nefteximicheskoy, nefteximicheskoy, nefteximicheskoy, boshqa protsessarlar o'tkazish.
Prinsept deystviya osnovan na uravnoveshivanii napryajeniya s termopreobrazovatelya padeniem napryajeniya na reohorde s pomoshchyu elektromexanicheskogo sledyaschego ustroystva.
D-datchik
VxU - o'rnatish
UBS - Usilitel vxodnogo signala (PU-predvaritelnyy usitel; Ok-okonechnyy usitel)
UR-uslitel signal reoxora
R - reoxord
DV-balansiruyushchiy dvigatel
UN-usitel nebalansa
VU1-VU4-vyxodnye qurilmasi
IP-istochnik pitaniya
Ustrostvo va rabota pribora
Signal s datchika D postupaet vo vxodnoe ustrostvo VxU, gde usilivaetsya va nastraivaetsya po nijnemu predelu izmereniya. Vo vxodnom ustroystve podklyuchena mednaya katushka R 6 uchun avtomaticheskogo vedeniya popravok na t s.k. Zatem signal postupaet v UVS, kotoryy sostoyt iz predvaritelnogo usitelya PU, gde napryajenie usilivaet v diapazon 0,04V va okonechno usitelya OU, gde signal nastraivaetsya ot -0,5 to +8,5V va postupaet na usillan. Na UN podaetsya signal s reoxorda R, usilennyy usilitelem reoxora UR diapazona ot 0,5 to 8,5V. Signal sravnivayutsya UN, ix raznost usilennaya podaetsya na reversivnyy dvigatel DV. Dvigatel mexanicheski (trosikom) svyazan s reoxordom peremeshchaet ego podvijnyy kontakt vpravo yoki vlevo, izmenyaya napryajenie na reohorde do tex por poka ne uravnyaet s napryajeniem s termopary. Pri etom dvigatel ostanovitsya i strelka pokajet izmeryaemuyu haroratu.
Texnika va metrologik xarakteristikalar.
Kolichestvo vxodov 1 yoki 2 nezavisimyh kanala
Vxodnye signaly: napryajeniya - (0-1), (0-10), (-10-0+10) V; toka - (0-5), (0-20), (4-20) mA.
Osnovnaya pogreshnost po pokazaniyam: +0,5%
Bystrodeystvie: 1; 2,5; 5 yoki 10 s.
Skorost peremeshcheniya diagrammasi - 20, 40, 80, 160, 320, 640, 1280 yoki 2560 mm/g.
Vxodnye ustroystva signalizatsii: dva dvuxpozitsionnyx ustroystva dve nezavisimye o'rnatish, kontakty, rele 220V.
Dlina shkaly va shirina diagrammnoy lenty (100 0,1) mm.
Rabochee polojenie shkal priborov - vertikalnoe
Pribor imeet indikatsiyu «pribor vklyuchen»
Pitanie silovoy tsepi priborov osushchestvlyaetsya ot seti peremennogo toka napryajeniem (220 -33 +22 ), chastotoy (50 1) Gts.
Moshchnost, potreblyaemaya silovoy tsepyu pribora pri nominalnom napryajenii pitaniya ne prevyshaet 18V*A.
Osnovnaya pogreshnost po registratsii 1,0
Variatsiya pokazaniy ne prevyshaet absolyutnogo znacheniya predela osnovnoy pogreshnosti po pokazaniyam.
Iz texnicheskogo opisaniya pribora normalnoy yavlyaetsya harorat okrujayuschey sredy: =(20±2) o S. Pri otklonenii temperatury ot normalnoy izmenie pogreshnosti pribora ne prevyshaet znacheniy, opredelyaemyh formula:
gde, - privedennaya pogreshnost,
K t - koeffitsient proporsionalnosti, , K=0,015
Absolyutnaya dopolnitelnaya pogreshnost za schet vliyaniya temperatury okrujayuscheho vozduxa v darajaah Tselsiya ravna:
,
Poverka rascheta:
,
,6 o C < 4 o C.
Neravenstvo vypolneno, sledovatelno, pribor vybran pravilno.
Do'stlaringiz bilan baham: |