3.5.4 Automation of a Garage Door
In complex machines, where a recurrent operation takes place, this is commonly achieved through
the utilization of a motor with the capability of rotation inversion, as has been indicated in Section
3.4.1. In the current application, the recurrent component is a garage door, which is equipped with
a motor with reverse capability. As indicated in Figure 3.27, a combined operation of the door
is necessary through the utilization of two limit switches (b
1
, b
2
) and one photocell-sensor (u).
The limit switches stop the movement of the door automatically (safety switches) when it reaches
the corresponding motion limit. The photocell is utilized for the detection of humans, in order
to instantly terminate the movement of the door upon human detection. The operation of this
ELS = electronic level switch
Pumps
ELS
2
ELS
1
E
2
E
1
ELS = electronic level switch
N
C
1
50 Hz 230 V
R
e
1
NC
ELS
1
RS
1
e
2
RS
2
C
2
NC
ELS
2
Do'stlaringiz bilan baham: |