Fire detection and warning
In the event of fi re it is vital that everyone in the work-
place is alerted as soon as possible. The earlier the fi re 
is discovered, the more likely it is that people will be able 
to escape before the fi re takes hold and before it blocks 
escape routes or makes escape diffi cult.
Every workplace should have detection and warning 
arrangements. Usually the people who work there will 
detect the fi re and in many workplaces nothing further 
will be needed.
It is important to consider how long a fi re is likely 
to burn before it is discovered. Fires are likely to be 
Figure 13.8
Various storage arrangement for highly fl am-
mable liquids.


Fire hazards and control
215
discovered quickly if they occur in places that are 
frequently visited by employees, or in occupied areas 
of a building. For example, employees are likely to smell 
burning or see smoke if a fi re breaks out in an offi ce.
Where there is concern that fi re may break out in 
an unoccupied part of the premises, for example, in 
a basement, some form of automatic fi re detection 
should be fi tted. Commercially available heat or smoke 
detection systems can be used. In small premises a 
series of interlinked domestic smoke alarms that can 
be heard by everyone present will be suffi cient. In most 
cases, staff can be relied upon to detect a fi re.
In small workplaces where occupancy is low, a 
shouted warning should be all that is needed, so long as 
the warning can be heard and understood everywhere 
on the premises.
If the size or occupancy of a workplace means that 
a shouted warning is insuffi cient, hand-operated devices 
such as bells, gongs or sirens can be used. They should 
be installed on exit routes and should be clearly audible 
throughout the workplace. In all other places an electric-
ally operated fi re alarm system should be fi tted. This 
will have call points adjacent to exit doors and enough 
bells or sounders to be clearly audible throughout the 
premises.
If it is thought that there might be some delay in 
fi re being detected, automatic fi re detection should be 
considered, linked into an electrical fi re alarm system. 
Where a workplace provides sleeping accommodation or 
where fi res may develop undetected, automatic detection 
must be provided. If a workplace provides sleeping 
accommodation for fewer than six people, interlinked 
domestic smoke alarms (wired to the mains electri-
city supply) can be used provided that they are audible 
throughout the workplace while people are present.

Download 5,86 Mb.

Do'stlaringiz bilan baham:
1   ...   335   336   337   338   339   340   341   342   ...   722




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2025
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish