2. Contents of packing 
1. The level gauge is delivered in 2 units (A and B). (see page 11) 
Unit A consists of: 

upper shutoff valve (2) 

gauge body (1) 

lower shutoff valve (3) 
Unit B consists of: 

illumination device (6, 7) 
2. Installation and operating instruction 
 
Caution 


10 
3. Important information 
The direct water level gauge is for measurement and control purposes and 
must only be used to display fill levels on a tank. Here care must be taken 
that pressure and temperature do not exceed the maximum limitations of 
use. These can be found on the identification plate. 
 
The operator of the direct water level gauge is responsible for the intended 
use of the indicator. 
Note! 
For displays weighing 30 kilograms or more, the customer must provide 
sufficient support (e.g. by spring hangers or similar). 
 
3.1 Intended use 
Bicolour level gauge

The bicolour level gauge type BU is a direct water level gauge with illumination which can be 
used for steam boilers and containers. 
This product is in accordance with EU-directive 2014/68/EU. Applied policy acc. to DIN EN 
13445 and ASME Boiler and Pressure Vessel Code. Considered regulations AD2000. 
Furthermore, as a plant component for large water room boilers and water tube boilers, this 
product meets the requirements of the standards DIN EN 12952-7 and DIN EN 12953-6. 
4. Explanations 
4.1 System description 
The bicolour level gauge in different versions is used to detect the water level of steam 
generators or containers. 
4.2 Function principle 
The device works on the principle of communicating pipes.
With the “BU green/red” model, the water level is shown by the rear LED illumination of the 
steam compartment: 
Red and green light falls on the display unit. If there is water in the display area, then the light 
rays will be diverted in such a way that the green light beam falls on to the slit diaphragm of 
the display box. In the steam area the light rays are not diverted and the red-light beam is 
projected. 
As a result, in the “BU green/red” model the water compartment always appears green and 
the steam compartment red. 
Caution
Caution
Caution 


11 
4.3 Versions 
Standard version 
Version with expansion loop 
Divided version 
Version with tie bar 


12 

Download 1,64 Mb.

Do'stlaringiz bilan baham:
1   ...   4   5   6   7   8   9   10   11   ...   21




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish