General Specification Electrical Function gmw3110 General Motors Local Area Network Enhanced Diagnostic Test Mode Specification



Download 8,35 Mb.
Pdf ko'rish
bet219/406
Sana03.04.2022
Hajmi8,35 Mb.
#525939
1   ...   215   216   217   218   219   220   221   222   ...   406
Bog'liq
gmw3110

Procedure 5: 
(If ECU implements this RC_).
 
1. Send a $3B message with a dataIdentifier and associated data bytes after the sub-parameter to the ECU 
when the ECU needs more than P2
C
ms to write data bytes to memory and verify the negative response 
($7F $3B $78 - RequestCorrectlyReceived-ResponsePending) within P2
C
ms and eventually a positive 
response message. 
Procedure 6: 
(If applicable).
 
1. If the ECU does any type of validity checks on the data being written, send a request with invalid data and 
verify the $7F $3B $31 negative response. 
Procedure 7:
(Only applicable if ECU has DIDs that require the usage of a security code). 
Note:
Security code as defined in the Vehicle Theft Deterrent SSTS 
1. Send a $3B message with a security code required dataIdentifier and associated data bytes after the 
dataIdentifier to a secured ECU (security code has not been entered) and verify the negative response 
($7F $3B $31 - RequestOutOfRange). 
2. Send a $3B message with a security code required dataIdentifier and associated data bytes after the 
dataIdentifier when the security code has been entered
 
and verify the positive response. 
3. Repeat steps 1 and 2 for each DID that requires the security code. 
8.14.8 Tester Implications. 
This service should be used with physical addressing.
 
 
CameraLoops.com


GM WORLDWIDE ENGINEERING STANDARDS 
GMW3110 
© Copyright 2010 General Motors All Rights Reserved 
February 2010 
Page 175 of 336 
8.15 TesterPresent ($3E) Service. 
This service is used to indicate to a node (or nodes) that a tester is still 
connected to the vehicle and that certain diagnostic services that have been previously activated are to remain 
active. Some diagnostic services require that a tester send a request for this service periodically in order to 
keep the functionality of the other service active. Documentation within this specification of each diagnostic 
service indicates if a given service requires the periodic TesterPresent request to remain active. 

Download 8,35 Mb.

Do'stlaringiz bilan baham:
1   ...   215   216   217   218   219   220   221   222   ...   406




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish