s
Motoring
Generating
Figure 10.1
Steady-state torque–speed curve for a synchronous motor supplied at
constant frequency
342
Electric Motors and Drives


machines, heating systems, etc. They are also used where precise integral
speed ratios are to be maintained: for example, a 3:1 speed ratio can be
guaranteed by using a 2-pole and a 6-pole motor, fed from the same
supply.
We will now look brie
X
y at the various types of synchronous motor,
mentioning the advantages and disadvantages of each. The excited-rotor
type is given most weight not only because of its importance in large
sizes but also because its behaviour can be analysed, and its mechanism
of operation illuminated, by means of a relatively simple equivalent
circuit. Parallels are drawn with both the d.c. motor and the induction
motor to emphasise that despite their obvious di
V
erences, most electrical
machines also have striking similarities.
Excited-rotor motors
The rotor carries a ‘
W
eld’ winding which is supplied with direct current
via a pair of sliprings on the shaft, and is designed to produce an air-gap
W
eld of the same pole number and spatial distribution (usually sinus-
oidal) as that produced by the stator winding. The rotor may be more
or less cylindrical, with the
W
eld winding distributed in slots (see Figure
10.2(a)), or it may have projecting (‘salient’) poles around which the
winding is concentrated (see Figure 10.2(b)). As the discussion in Section
10.2 revealed, a cylindrical-rotor motor has little or no reluctance torque,
so it can only produce torque when current is fed into the rotor. On the
other hand, the salient-pole type also produces some reluctance torque
even when the rotor winding has no current. In both cases, however, the
rotor ‘excitation’ power is relatively small, since all the mechanical
output power is supplied from the stator side.
Excited-rotor motors are used in sizes ranging from a few kW up to
several MW. The large ones are e
V
ective alternators (as used for power
(a)
(b)
Figure 10.2
Rotors for synchronous motors. 2-pole cylindrical (a) with
W
eld coils
distributed in slots, and 2-pole salient pole (b) with concentrated
W
eld winding
Synchronous, Brushless D.C. and Switched Reluctance Drives
343


generation) but used as motors. Wound-rotor induction motors (see
Chapter 6) can also be made to operate synchronously by supplying
the rotor with d.c. through the sliprings.
The simplest way to visualise the mechanism of torque production is
to focus on a static picture, and consider the alignment force between the
stator and rotor
W
eld patterns. When the two are aligned with N facing
S, the torque is zero and the system is in stable equilibrium, with any
displacement to right or left causing a restoring torque to come into
play. If the
W
elds are distributed sinusoidally in space, the restoring
torque will reach a maximum when the poles are misaligned by half a
pole pitch, or 90
8
. Beyond 90
8
the torque reduces with angle, giving
an unstable region, zero torque being reached again when N is opposite
to N.
When the motor is running synchronously, we can use much the same
mental picture because the
W
eld produced by the 3-phase alternating
currents in the stator windings rotates at precisely the same speed as
the
W
eld produced by the d.c. current in the rotor. At no-load there is
little or no angular displacement between the
W
eld patterns, because the
torque required to overcome friction is small. But each time the load
increases, the rotor slows momentarily before settling at the original
speed but with a displacement between the two
W
eld patterns that is
su
Y
cient to furnish the torque needed for steady-state running. This
angle is known as the ‘load-angle’, and we can actually see it when we
illuminate the shaft of the motor with a mains-frequency stroboscope: a
reference mark on the shaft is seen to drop back by a few degrees each
time the load is increased.
Equivalent circuit of excited-rotor synchronous motor
Predicting the current and power-factor drawn from the mains by a
cylindrical-rotor synchronous motor is possible by means of the very
simple per-phase a.c. equivalent circuit shown in Figure 10.3. In this
circuit
X
s
(known as the synchronous reactance) represents the e
V
ective
inductive reactance of the stator phase winding;
R
is the stator winding
resistance;
V
the applied voltage and
E
the e.m.f. induced in the stator
winding by the rotating
W
eld produced by the d.c. current on the rotor.
(For the bene
W
t of readers who tackled Chapter 7, it should be pointed
out that
X
s
is e
V
ectively equal to the sum of the magnetising and leakage
reactances, i.e.
X
s
¼
X
m
þ
X
1
: but because the air-gap in synchronous
machines is usually larger than in induction motors, their per unit
synchronous reactance is usually lower than that of an induction ma-
chine with the same stator winding.)
344
Electric Motors and Drives


The similarity between this circuit and that of the d.c. machine (see
Figure 3.6) and the induction motor (see Figure 5.8) is clear, and it stems
from the fact that these machines produce torque by the interaction of
a magnetic
W
eld and current-carrying conductors (the so-called ‘
BIl

e
V
ect). In the case of the d.c. machine the inductance was seen not to
be important under steady-state conditions, because the current was
steady (i.e. d.c.), and the resistance emerged as the dominant parameter.
In the case of the mains-fed synchronous motor the current is alternat-
ing at mains frequency, so not surprisingly we
W
nd that the synchronous
reactance is the dominant impedance and resistance plays only a minor
role.
At this point readers who are not familiar with a.c. circuit theory can
be reassured that they will not be seriously disadvantaged by skipping
the rest of this and the following sections. But although no seminal
truths are to follow, discussion of the equivalent circuit and the associ-
ated phasor diagram greatly assists the understanding of motor behav-
iour, especially its ability to operate over a range of power factors.
Our aim is to
W
nd the current drawn from the mains, which from
Figure 10.3 clearly depends on all the parameters therein. But for a given
machine operating from a constant-voltage, constant-frequency supply,
the only variables are the load on the shaft and the d.c. current (the
excitation) fed into the rotor, so we will look at the in
X
uence of both,
beginning with the e
V
ect of the load on the shaft.
The speed is constant and therefore the mechanical output power
(torque times speed) is proportional to the torque being produced,
which in the steady state is equal and opposite to the load torque.
Hence if we neglect the losses in the motor, the electrical input power
is also determined by the load on the shaft. The input power per phase is
given by
VI
cos
f
, where
I
is the current and the power-factor angle is
f
.
But
V
is
W
xed, so the in-phase (or real) component of input current
(
I
cos
f
) is determined by the mechanical load on the shaft. We recall

Download 5,24 Mb.

Do'stlaringiz bilan baham:
1   ...   75   76   77   78   79   80   81   82   ...   97




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish