Chapter 3 Measurement of Be-7 in Environmental Materials A. R. Iurian and G. E. Millward



Download 0,64 Mb.
Pdf ko'rish
bet14/19
Sana03.07.2021
Hajmi0,64 Mb.
#108690
1   ...   11   12   13   14   15   16   17   18   19
Bog'liq
Iurian-Millward2019 Chapter MeasurementOfBe-7InEnvironment

Glossary

The energy resolution (FWHM)

The full width of the peak at one-

half of the maximum height above

any underlying continuous spec-

tral background.

1

Absolute efficiency



The ratio between the number of

pulses recorded and the number

of radiation quanta emitted by

source.


Relative efficiency

Detector efficiency relative to that

of a NaI(Tl) detector.

2

Peak-to-Compton ratio



The ratio of the number of counts

in the biggest channel of the

1332.50 keV

60

Co energy peak



to the average channel count in

the Compton continuum between

1040 and 1096 keV in the same

spectrum.

Coincidence summing correction factor

The ratio between the appar-

ent efficiency for the line with

energy E of the nuclide hav-

ing cascading radiations, to the

full energy peak efficiency at

the same energy obtained from

the energy curve measured with

single-photon emitting radionu-

clides. The apparent activity (cor-

rected for background) must be

multiplied by the coincidence

summing correction factor to

1

Debertin and Helmer (



1988

).

2



Knoll (

2000


).


3

Measurement of Be-7 in Environmental Materials

41

obtain the true activity value for



the radionuclides affected by cas-

cade effect.

3

Geometry and self-attenuation correction factor The ratio of the full energy



peak efficiency for the sample

and the full energy peak effi-

ciency for the calibration stan-

dard. The correction is commonly

performed through an efficiency

transfer approach, by multiplying

the correction factor with the

7

Be



full energy peak efficiency.

Efficiency transfer

The “transfer” of the efficiency

of a standard to another sample,

which can be in the same geome-

try or not, and acting as corrective

factor for both geometry and self-

absorption effect.

Minimum Detectable Activity (MDA)

The lowest activity value that can

be detected with a measuring sys-

tem at 95% confidence.

4

Detection Limit (LD)



The lowest expectation value of

the counting rate of a net peak area

that can be detected with a measur-

ing system.




Download 0,64 Mb.

Do'stlaringiz bilan baham:
1   ...   11   12   13   14   15   16   17   18   19




Ma'lumotlar bazasi mualliflik huquqi bilan himoyalangan ©hozir.org 2024
ma'muriyatiga murojaat qiling

kiriting | ro'yxatdan o'tish
    Bosh sahifa
юртда тантана
Боғда битган
Бугун юртда
Эшитганлар жилманглар
Эшитмадим деманглар
битган бодомлар
Yangiariq tumani
qitish marakazi
Raqamli texnologiyalar
ilishida muhokamadan
tasdiqqa tavsiya
tavsiya etilgan
iqtisodiyot kafedrasi
steiermarkischen landesregierung
asarlaringizni yuboring
o'zingizning asarlaringizni
Iltimos faqat
faqat o'zingizning
steierm rkischen
landesregierung fachabteilung
rkischen landesregierung
hamshira loyihasi
loyihasi mavsum
faolyatining oqibatlari
asosiy adabiyotlar
fakulteti ahborot
ahborot havfsizligi
havfsizligi kafedrasi
fanidan bo’yicha
fakulteti iqtisodiyot
boshqaruv fakulteti
chiqarishda boshqaruv
ishlab chiqarishda
iqtisodiyot fakultet
multiservis tarmoqlari
fanidan asosiy
Uzbek fanidan
mavzulari potok
asosidagi multiservis
'aliyyil a'ziym
billahil 'aliyyil
illaa billahil
quvvata illaa
falah' deganida
Kompyuter savodxonligi
bo’yicha mustaqil
'alal falah'
Hayya 'alal
'alas soloh
Hayya 'alas
mavsum boyicha


yuklab olish