68. C. You will need a virtual router running static NAT to translate the two different IP
networks. This type of service is called a virtual network function, or VNF. A virtual
switch is built into just about every virtualization platform, since layer 2 communications
are normally required. A virtual firewall is a piece of software that allows you to protect
your virtualization infrastructure, just like their hardware counterparts. Another IP
scheme at the provider could help, but a router would still be required for connectivity.
69. C. Network Time Protocol (NTP) is a standardized protocol for network time
synchronization. Domain Name System (DNS) is a service that is used to translate a qualified
domain name (FQDN) to an IP address. The rsync utility is a Linux/Unix utility used to
synchronize (copy) a number of files to a remote system. A virtual private network (VPN) is a
private encrypted tunnel that is normally created over a public Internet connection.
70. B. You would use a crossover cable because a switch is a data communications equipment
(DCE) Ethernet device. When connecting a DCE Ethernet device to another DCE Ethernet
device, you would need to cross the connection with a crossover cable. Newer switches
have medium dependent interface-crossover (MDI-X) capabilities to detect the need
for a crossover cable and will automatically switch the cable over if a straight-through
cable is used. A straight-through cable is used to connect a DCE Ethernet device such
as a switch to data terminal equipment (DTE) such as a host. A rolled cable is used for
serial communication between a router or switch and a modem or serial adapter for
configuration. A shielded cable has either a metal webbed shield or foil shield to filter out
electrical magnetic interference (EMI).
71. B. Multi-mode fiber can be either 50 microns or 62.5 microns at its core. The maximum
distance for a 50-micron fiber is 550 meters utilizing the 1000Base-LX specification.
Unshielded twisted pair (UTP) is used in copper Ethernet cabling of hosts and network
equipment. Single-mode fiber-optic cable is around 7 microns thick and is used for long-
distance communications. Shielded twisted pair (STP) is used in industrial settings when
there is the potential for electrical magnetic interference (EMI).
72. C. Although operation of computers connected to a switch uses a straight-through cable,
management via the console port requires a rolled cable and an EIA/TIA 232 adapter.
A straight-through cable is used to connect a data communications equipment (DCE)
Ethernet device such as a switch to data terminal equipment (DTE) such as a host. You
would use a crossover cable when connecting a DCE Ethernet device to another DCE
Ethernet device; you would need to cross the connection with a crossover cable. Newer
switches have medium dependent interface-crossover (MDI-X) capabilities to detect
the need for a crossover cable and will automatically switch the cable over if a straight-
through cable is used. A shielded cable has either a metal webbed shield or foil shield to
filter out electrical magnetic interference (EMI).
73. C. 10GBase-CX is commonly used in data centers. It is referred to by its nickname of
Twinax. It is a fixed, balanced coaxial pair that can be run up to 25 meters. 10GBase-T
is usually category 6 cable that is nominally run up to 55 meters in length to achieve
10 Gb/s speeds. 40GBase-T is usually category 8 cable that is nominally run up to 30
meters to provide 40 Gb/s speeds. 100GBase-TX is not a valid specification for Ethernet
connectivity. 100Base-TX is standard 100 Mb/s connectivity that supports full-duplex
communications.